10.1
check pressure readings
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read as described on the chart
below. Check pressure with main burner operating on "HI".
Outlet pressure can be checked the same as above using screw
(B). Gauge should read as described on the chart below. Check
pressure with main burner operating on "HI".
After taking pressure readings, be sure to turn screws
clockwise fi rmly to reseal. Do not overtorque.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting of
the pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or a
synthetic scrub pad (such as Scotch-Brite™) can be used to remove the paint from the pilot hood, electrode
and fl ame sensor.
Pressure
Natural Gas
(inches)
Inlet
(minimum 4.5")
Outlet
Natural Gas
(millibars)
*7"
17.4mb
(minimum 11.2mb)
3.5"
8.7mb
B
PILOT OUTLET
10.0 adjustments
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
INSERT PILOT ASSEMBLY
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
Propane
(inches)
13"
(minimum 11")
(minimum 27.4mb)
10"
*Maximum inlet pressure not to exceed 13"
TOP VIEW
A
SIDE VIEW
adjustment
Propane
(millibars)
32.4mb
24.9mb
55