Mounting the vertical stay
4.
Insert the required vertical uprights on around the basin.
5.
Fit the vertical uprights into the ground rail connectors with 2 self-
tapping screws. The flaps of the connectors must be inside.
6.
Place the top plate on the pier, so that the flaps remain on the in-
side of the post and secure it with 3 selfthreading screws. Make
sure that the pile is completely
vertical. Figure 33, 34
Mounting of the hand rails
6.
Install a hand rail and position by first one of the ends over the top
of the plate. The side of the hand rails, which remains inside the
swimming pool, must be in the vicinity of the film or of the panel
and the wall of the
pool. Figure 35
7.
Align the holes out as shown. Secure it in place with 2 screws on
the top plate. Tighten the screws until all hand rails have been in-
stalled at their place. Figure
36
8.
Repeat steps 1 and 2 with all the hand rails.
9. Form a perfect circle.
10.
Adjust the hand rails, so they all have the same distance of each
other and tighten the screws.
Installation of decorative caps
4.
Create the first decorative cap on the ends of the two hand rails
and hook it on the inner edges of the hand rails.
5.
Pull the decorative cap beyond the outer edge of the handrail and
hook the cap.
6.
Repeat these steps to attach the rest of the decorative
re 37
Installation of the inlet nozzle and skimmer
Connector openings for built-in elements (skimmer and nozzles):
The openings for the built-in elements are not completely punched
out in the factory. Therefore the inner metal piece (on the perforated
areas) must be released carefully using an appropriate tool, and the
edges filed down. Then treat the edges with appropriate protection
from corrosion (e.g. rust protection or zinc paint).
Also note the information in the description of the skimmer.
Continue filling your pool.
Keep on filling the swimming pool with water until 5 cm below the
cutted inlet nozzle.
Scan the circle in the pelvic wall and make a cross-section with a
sharp knife (stanley knife), without cutting out beyond the punching
out! Figure 27
Insert the inlet nozzle with a seal of the tank wall inside through to
the outside. The resulting film triangles on the outside should be cut
off along the nozzle clean and accurate.
Now bring on the second seal on the outside of the inlet nozzle and
screw it together with the plastic nut. Tighten the inlet nozzle orderly
(Caution: do not overtighten!).
Figure 28
4) seals
5)
steel jacket
6)
swimming pool liner
If your inlet nozzle should be equipped with a loose pump connec-
tion piece, it is necessary to seal the threads with Teflon tape!
After placing the inlet nozzle properly, keep on filling the swimming
pool with water until 5 cm below the skimmer.
First, plug the skimmerflap into the skimmercase. Depending on the
design of the skimmer there are 2 seals individually or 1 lip seal in-
cluded.
Page 8 of 38
Assembly with two skimmer seals
Take the skimmer flange and a seal and plug one screw at each top
on the right and left. Now scan the both openings in the foil and the
corresponding holes from the steel wall and pierce them through
with a pointed end. Plug the two screws with the skimmer flange and
the seal from the inside through to the outside and put on the second
seal on the two screws on the tank wall outside. Now onto the pool
wall outside the skimmer has to be fixed with the two screws. As a
result, the remaining holes are punched in the foil and pushed
through the separately screws and bolt together with the skimmer
case. Be sure that the skimmer seals are mounted even all round.
Tighten the screws diagonally and evenly to ensure tightness. The
tightening of the screws may only be done by hand, because not to
overtighten the screws (don't use a cordless screwdriver). As a re-
sult, the film square is cut with a sharp knife (Stanley knife) within
the skimmer flange.
Assembly with V-shaped skimmer seal
Replace the lip seal on the skimmer section. Note the flange holes!
Proceed the same as previously described above.
Figure 29
5) steel jacket
6) swimming pool liner
7) seals
8) skimmer flange
After connection to the filter
caps. Figu-
mately half the
If your skimmer should be equipped with a loose pump connection
piece, it is necessary to seal the threads with Teflon tape!
End of season
At the end of the season decrease the water level just below the
skimmer opening or inlet nozzle of the pool. In addition, the connect-
ing tubes to the filter plant have to be dismantled. The filter system
or filter pump is drained by opening the drain plugs. Filter systems
located outdoor must be accommodated in a frost-fre room in the
winter.
We recommend a winterization only when the water temperature is
below 12 degrees.
Damage caused by freezing isn't covered by warranty!
Figure 29
system, the water
is filled to approxi-
skimmer. (Figure 30)
Nuovo deluxe Duo rund | 2020_V2