CAL 14
CH1. Not used.
CAL 15
CH1. Not used.
CAL 16
CH2. DC offset zero.
CAL 17
CH2. DC offset at + full−scale.
CAL 18
CH2. DC offset at − full−scale.
CAL 19
CH2. Multiplier zero.
CAL 20
CH2. Multiplier offset.
CAL 21
CH2. Waveform offset.
CAL 22
CH2. Output level at full−scale
CAL 23
CH2. 20dB attenuator
CAL 24
CH2. 40dB attenuator
CAL 25
CH2. 10dB attenuator
CAL 26
CH2. Sum offset.
CAL 27
CH2. SCM level at full−scale.
CAL 28
CH2. AM level at full−scale.
CAL 29
CH3. DC offset zero.
CAL 30
CH3. DC offset at + full scale.
CAL 31
CH3. DC offset at − full scale.
CAL 32
CH3. Multiplier zero.
CAL 33
CH3. Multiplier offset.
CAL 34
CH3. Waveform offset.
CAL 35
CH3. Output level at full−scale
CAL 36
CH3. 20dB attenuator
CAL 37
CH3. 40dB attenuator
CAL 38
CH3. 10dB attenuator
CAL 39
CH2. Sum offset.
CAL 40
CH3. SCM level at full−scale.
CAL 41
CH3. AM level at full−scale.
CAL 42
CH4. DC offset zero.
CAL 43
CH4. DC offset at + full scale.
CH4. DC offset at − full scale.
CAL 44
CAL 45
CH4. Multiplier zero.
CAL 46
CH4. Multiplier offset.
CAL 47
CH4. Waveform offset.
CAL 48
CH4. Output level at full−scale
CAL 49
CH4. 20dB attenuator
CAL 50
CH4. 40dB attenuator
CAL 51
CH4. 10dB attenuator
CAL 52
CH4. Sum offset.
CAL 53
CH4. SCM level at full−scale.
CAL 54
CH4. AM level at full−scale.
CAL 55
Clock calibrate
Adjust for 0V ± 5mV.
Adjust for +10V ± 10mV.
Check for –10V ± 3%
Adjust for minimum Volts AC
Adjust for 0V ± 5mV.
Adjust for 0V ± 5mV.
Adjust for 10V ± 10mV.
Adjust for 1V ± 1mV.
Adjust for 0·1V ± ·1mV.
Adjust for 2·236V AC ± 10mV.
Adjust for 0V ± 5mV.
Adjust for 5V ± 5mV.
Adjust for 10V ± 10mV.
Adjust for 0V ± 5mV.
Adjust for +10V ± 10mV.
Check for −10V ± 3%
Adjust for minimum Volts AC
Adjust for 0V ± 5mV.
Adjust for 0V ± 5mV.
Adjust for 10V ± 10mV.
Adjust for 1V ± 1mV.
Adjust for 0·1V ± ·1mV.
Adjust for 2·236V AC ± 10mV.
Adjust for 0V ± 5mV.
Adjust for 5V ± 5mV.
Adjust for 10V ± 10mV.
Adjust for 0V ± 5mV.
Adjust for +10V ± 10mV.
Check for −10V ± 3%
Adjust for minimum Volts AC
Adjust for 0V ± 5mV.
Adjust for 0V ± 5mV.
Adjust for 10V ± 10mV.
Adjust for 1V ± 1mV.
Adjust for 0·1V ± ·1mV.
Adjust for 2·236V AC ± 10mV.
Adjust for 0V ± 5mV.
Adjust for 5V ± 5mV.
Adjust for 10V ± 10mV.
Adjust for 10·00000 MHz at SYNC OUT.
71