If several menu items are shown, the scroll function (cursor
keys) can be used to scroll up and down.
Menu headings are always shown in the first line
The last line of the display field is reserved for errors, mes-
sages and events (A third category – message – is added to
the two categories errors and events.)
From 16 characters onwards, the text is shown as running
text. (Selected field + corresponding character length acti-
vates the running text)
If no keys are pressed for 1 minute, the device returns to the
system info menu item.
When a password has been entered, this is cleared as long
as the display lighting is illuminated.
Message IDs
Availability depending on the control unit or system configuration
General
ID
1
First initialisation
2
Device initialised
3
Factory settings
4
Acoustic alarm acknowledged
5
Error acknowledged
6
Maintenance done
7
Parameter changed
8
Expert parameter changed
9
Manual operation
10
Log book read
11
Sensor configuration changed
12
Control unit shut down
13
Battery monitoring activated
14
Battery monitoring deactivated
15
USB detected
16
Software update
17
Parameter read in
18
Maintenance due
19
Power outage
20
Battery error
21
Alarm temperature exceeded
22
Watchdog was active
23
Goes into sleep mode
24
SDS successful
25
SDS not successful
26
SDS interrupted
27
Rotary field error
28
Phase error
29
Program read in
30
Legionella flushing active
31
Alarm level exceeded
32
Filling interrupted
33
Save USB
434-033
Event
Vers.: 1
6. Error acknowledgement
If an error occurs, it can simply be acknowledged by SMS. To
do this, send back an SMS with no content or any content as a
reply.
SMS messages
Parameter
Message ID
The message code is stored
in the appendix, see „Mes-
sage IDs".
Message text
The message text is stored in
the appendix, see „Message
IDs".
Station name
Set name in the communica-
tion menu of the control unit
for SMS transmission
ID
34
SonicControl maintenance acknowledged
35
Standard disposal acknowledged
36
Disposal interrupted
37
Operating mode / system type changed
38
Expert parameters read in
39
Undervoltage
40
Overvoltage
41
Warning temperature exceeded
42
Mains voltage switched on
43
Invalid log
Pumps and motors
ID
51
Motor protection triggered
52
Relay error pump 1
53
Thermal protection 1A triggered
54
Thermal protection 1B triggered
55
Overcurrent pump 1
Overcurrent pump
56
Undercurrent pump 1
Undercurrent pump
57
Maximum operating cycles for pump 1 exceeded
58
Overcurrent pump 2
59
Undercurrent pump 2
60
Maximum operating cycles for pump 2 exceeded
61
Thermal protection 2A triggered
62
Thermal protection 2B triggered
63
Max run time 1
Max. run time
64
Max. number of runs 1
Max. number of runs
65
Max run time 2
66
Max. number of runs 2
67
Relay error pump 2
68
Pump stopped
2024-08
Description
SMS
identifier
ID
-
Event
Event
7 / 28