INSTALLATION AND
CONNECTION
SELECTING THE ROOM
• Install the appliance in a dry and well ventilated room. The appliance will
operate correctly if the environment temperature is in the interval specifi ed in
the table. The appliance class is indicated on the rating plate / label with the
basic information on the appliance.
Class
SN (subnormal)
N (normal)
ST (subtropical)
T (tropical)
i
• Do not place an appliance in a room where temperature can drop to
below 5 °C as this may cause abnormal appliance operation or failure!
• After the installation, the appliance mains plug should be accessible!
Note: Place the appliance in a suffi ciently large room. There should be at least
1 m
3
of space per 8 grams of refrigerant. Amount of refrigerant is indicated on
the rating plate in the appliance interior.
• At the base of the kitchen unit intended for building in the integrated
appliance, there should be at least 200 cm
circulation.
On the upper part of the appliance the air is coming out, so try not to cover
the opening for the outfl ow air. Ignoring this caution may result in damage to
the appliance.
Warning: when installing built-in appliances into a cupboard or cabinet in a
side-by-side layout, the dew prevention installation kit should also be purchased
and installed. For safety reasons, dew prevention kit may only be installed by
an authorized service technician!
Temperature
from +10 °C to +32 °C
from +16 °C to +32 °C
from +16 °C to +38 °C
from +16 °C to +43 °C
2
free space, for adequate air
Relative Humidity
75%
11