NOT RECOMMENDED AS PRIMARY HEAT SOURCE
SAFETY NOTICE: If this heater is not properly installed, a
house fire may result. For your safety, follow the installation
instructions. Contact your local building or fire officials
about obtaining a permit, restrictions and installation
requirements in your area.
CAUTION: Read All Instructions Carefully Before Starting The
Installation or Operating This Heater. Improper Installation
Could Void Your Warranty!
ALL PICTURES SHOWN ARE FOR ILLUSTRATIVE PURPOSES
ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT
ENHANCEMENT.
This manual is subject to change without notice.
WALL MOUNTED PELLET UNIT
MODEL AP5000
U.S. Patent No. 9,752,778
United States Stove Company
227 Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com
Report #: F20-598
Certified to ASTM Std E1509-12 (2017) and
Certified to ULC S627-00
U.S. Environmental Protection Agency
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
Certified to comply with 2020 particulate
carbone, lesquels sont reconnus dans l'État de la Californie comme causant le cancer et
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
emissions standards.
renseignements, veuillez consulter le site www.P65warnings.ca.gov
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
SAVE THIS MANUAL FOR FUTURE REFERENCE
THIS MANUAL WILL HELP YOU TO OBTAIN
EFFICIENT, DEPENDABLE SERVICE FROM
THE HEATER, AND ENABLE YOU TO ORDER
REPAIR PARTS CORRECTLY. KEEP IN A SAFE
PLACE FOR FUTURE REFERENCE.
R
853627B-2502J

Publicité

loading

Sommaire des Matières pour United States Stove Company Ashley AP5000

  • Page 1 THE HEATER, AND ENABLE YOU TO ORDER This manual is subject to change without notice. REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. United States Stove Company 227 Industrial Park Rd., South Pittsburg, TN 37380 PH: (800) 750-2723 www.usstove.com...
  • Page 2 Safety Precautions This manual describes the installation and operation of the Ashley, AP5000 wood heater. This heater meets the 2020 U.S. Environmental protection agency’s crib wood emission limits for wood heaters sold after may 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 8,141 to 12,161 btu/ hr output.
  • Page 3 Specifications Heating Specifications Heating Capacity 500 - 1,000 sq. ft. Fuel Burn Rate 3/4 - 2 1/2 lbs./hr. Burn Time (lowest setting) 35 hours Hopper Capacity 28 lbs *Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results.
  • Page 4 Installation INSTALLATION OPTIONS Side Wall To Stove 6” (152 mm) Read this entire manual before you install and use your pellet Front Of Stove 24” (607 mm) stove. Failure to follow instructions may result in property damage, Ceiling To Stove (allow bodily injury, or even death! Before installing your heater, you 18”...
  • Page 5 WALL INSTALLATION Select a wall to the exterior of the building. This wall should have the required clearance to combustibles inside and out as mentioned in this manual. Make certain that electrical wires, conduit, water or gas pipes do not pass through the area you have selected.
  • Page 6 You must use the Duravent FasNSeal Concentric Vent System designed to work with this appliance from United States Stove Company. DO NOT substitute other venting systems. The 3” x 5” horizontal square termination kit (35CVS-KUS) includes: •...
  • Page 7 1. DirectVent Pro pipe and fittings are designed with special twist-lock connections. To connect the venting system to the appliance flue outlet, a twist-lock Appliance Adaptor is required. The adaptor will be supplied for installation in the field. Assemble the desired combination of Pipe Sections and Elbows to the Appliance Adaptor.
  • Page 8 Understanding Your Heater HOW YOUR HEATER WORKS Your pellet heater operates on a timer based auger fuel feed system, that is controlled by a digital circuit board. The fuel is delivered from the auger into a burn pot, which is the vessel where the combustion process takes place.
  • Page 9 UNIT PREPARATION After properly installing your heater, you will need to attach the electrical cord to the right side blower housing first; then plug it into a 110 Volt outlet (an outlet surge protector is highly recommended). PERFORMING AN INITIAL BURN You must perform an initial burn in this appliance before installing it in your home or garage.
  • Page 10 NOTE: The unit will also shut down in the event of an exhaust blower failure; if this is the case, the unit will not re- start and you must contact Customer Service. The amount of visible smoke being produced can be an effective method of determining how efficiently the combustion process is taking place at the given settings.
  • Page 11 INTERIOR CHAMBERS Periodically remove and clean the burn pot, flame impingement plate and the areas behind the cleanout door. In particular, it is advisable to clean out the holes in the burn pot to remove any build up that may prevent air from moving through the burn pot freely.
  • Page 12 unit with broken glass. Replacement glass may be purchased from your U.S. Stove Pellet Burning Room Heater Dealer. If glass is broken, follow these removal procedures: 1. Remove the retainers and any broken glass or gasket from the sealing face of the door. 2.
  • Page 13 Trouble Shooting Errors • Disconnect the power cord before performing any maintenance! NOTE: Switching the appliance to ”OFF” does not disconnect all power to the electrical components of the heater. • Never try to repair or replace any part of the heater unless instructions for doing so are given in this manual or supplied from the factory.
  • Page 14 Parts Diagram -14-...
  • Page 15 Parts List Part # Description 893318 Distribution Fan Enclosure Panel 893319 Distribution Fan Enclosure 3" Double Centrifugal Blower - 80542 125CFM 26210 Room Fans Extenders 80619 Ignitor Cartridge 80529 Auger Motor Pressure Switch/PC Board 26211 Mounting Bracket 69814 Door Switch Assembly 892004 Magnet 88118 Ignitor Flange Gasket...
  • Page 16 Wiring Diagram -16-...
  • Page 17 Notes -17-...
  • Page 18 Service Record It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. Service Provider: Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
  • Page 19 1. Le numéro de pièce _________________________________________________________________ 2. La description de la pièce ___________________________________________________________ 3. Le numéro de modèle _______________________________________________________________ 4. Le numéro de série __________________________________________________________________ United States Stove Company 227 Industrial Park Rd., South Pittsburg, TN 37380 PH: (800) 750-2723...
  • Page 21 CÂBLE RUBAN ROUGE NOIR BLANC ROUGE BLEU ORANGE...