2.4. CONNECTING TO THE POWER SUPPLY

3. FUNCTION

3.1. CONTROL PANEL AND OPERATING MODES

16
After installing the filter, remove the cable ties from the power cable and insert the plug into the outlet. After
the power supply is connected, the POWER symbol on the control panel will be illuminated red. The device
will then be in Standby mode.
CAUTION:
Observe the permitted power supply under the TECHNICAL DATA.
Switching on and o
Insert the plug into the outlet and the device will go into Standby mode. The button will be illuminated red.
Press the "POWER" button to switch o the device. The button will be illuminated green. Pressing the button
once again will switch the device back into Standby mode.

Automatic mode

When the device is switched o , press the "AUTO" button so that the symbol is illuminated. The anion
generator and sterilising UV light will be activated, and the purification level will be set/changed according to
the sensor data. Note: If users change the "ventilation speed" in Automatic mode, the device will leave this
mode.

Timer function

When the device is switched on, each time the "TIMER" button is pressed, this will extend the run time of the
air purifier by 1 hour. After this time, the device will switch to Standby mode. The maximum duration is 12
hours. Pressing the button a 13th time shuts o the timer.
Anion cleaning unit
When the device is switched on, pressing the "ANION" button will activate Anion mode. Pressing it again will
deactivate this mode.
Reset button, function 1
The air purifier has a regular reminder function for cleaning the filter:
Flashing every 320 hours: Cleaning the pre-filter
Continuously illuminated every 1500 hours: Cleaning the cold catalytic filter/activated carbon filter and
cotton/HEPA filter. At this time, press and hold the button for 5 seconds to reset the internal timer.
Reset button, function 2
CAUTION:
Press the filter button briefly to display the operating hours.
.
Sleep mode
When the device is switched on, it will change to Sleep mode 5 seconds after the "SLEEP" button is pressed.
All lights will be switched o and the machine will run in the first level. Press any button to activate the device,
then press the "SLEEP" button to leave Sleep mode, or press the "SPEED -" / "SPEED +" / "AUTO" buttons to
end the device after waking.
Child safety feature
When the device is switched on, pressing the "CHILD LOCK" button will lock all buttons. The device will
continue to work as normal. If you press the "CHILD LOCK" button for 5 seconds, the device will leave this
model.