Troubleshooting
Before calling for service, review this list. It may save you both time and expense. This list includes common experiences that
are not the result of defective workmanship or material in your appliance.
Problem
Surface Control Knob has not been completely turned to
until burner ignites and then turn control to desired flame size.
Surface burners do not
Ensure gas supply valve is open.
light
Burner ports or slots are clogged. With the burner off, use a small-gauge wire or needle to clean ports or slots.
Low gas supply level in cylinder.
Moisture is present on the burner, dry burner thoroughly.
Surface burner flame
Burner ports or slots are clogged. With the burner off, clean ports with a small-gauge wire or needle to clean ports or slots.
burns half way around
Moisture is present after cleaning. Lightly fan the flame and allow burner to operate until flame is full. Dry the burners thoroughly.
Dust particles in main line. Allow the burner to operate a few minutes until flame turns blue.
Surface burner flame
is orange
In coastal areas, a slightly orange flame is unavoidable due to salt air.
Specification
Left and Right Burner: 6500 BTU/HR
BTU/HR
Front Burner: 8000 BTU/HR
Oven: 7100 BTU/HR
Fuel / Power
Propane
Inlet Pressure
10" WC Min to 13.8" WC Max
Power Input
12V DC < 2 Amp (10.5V to 14.6 VDC)
17" Range Oven: 35L
Inner Volume of
the Oven
21" Range Oven: 51L
This appliance conforms with the directives: ANSI Z21.57a-(2012) Rec / CAN1-1.16-M79 (R2016)
Possible Causes / Solution
position. Push in and turn the Surface Control knob to
Technical Specifications
- 14 -
position
CCD-0005503 Rev: 01-17-23

Publicité