Télécharger Imprimer la page

GE Appliances Zoneline 4100 Serie Manuel D'utilisation Et Instructions D'installation page 6

Publicité

Auxiliary controls on your Zoneline.
Freeze Sentinel/Heat Sentinel
MODE 3
In the default setting for Mode 3, Heat Sentinel is off, Freeze
Sentinel is on.
Press MODE until a 3 appears in the first digit of the display for
Freeze Sentinel mode. The COOL LED light on the main control
will be on. Press MODE again to change to the Heat Sentinel. The
HEAT LED light on the main control will be on. Press the down
arrow for OFF "
in the second digit of the display. Press AUX SET to confirm your
selection and exit AUX SET mode, or press MODE to continue
setting other functions.
When Freeze Sentinel is activated, it automatically provides
heat without user interface. This helps to prevent plumbing
damage by turning the heater and indoor fan ON at 41ºF and
OFF at 46ºF.
When Heat Sentinel is activated, it automatically provides
cooling without user interface. This helps to prevent an
excessively hot room by turning the air conditioner ON at 85ºF
and OFF at 80ºF.
NOTE: These functions are active whenever the unit is
plugged in, even if the unit is in the STOP position.
Constant ON Fan
MODE 4
The default setting for Mode 4 is OFF.
Press MODE until a 4 appears in the first digit of the display to set
the fan to run continuously at high speed, even if the unit is in
the STOP position. Press the down arrow for OFF "
arrow for ON "
display. Press AUX SET to confirm your selection and exit AUX
SET mode, or press MODE to continue setting other functions.
Temperature Limiting
MODE 5
The default setting for Mode 5 is as follows:
Cool: 0 (60ºF to 85ºF)
Heat: 7 (60ºF to 85ºF)
Press MODE until a 5 appears in the first digit of the display for
Temperature Limiting cool mode. The COOL LED light on the
main control will be lit. To change to heat mode, press MODE
again and the HEAT LED light on the main control will be lit. To
set the temperature limits, press the up or down arrow keys. The
second digit of the display will be between 0 and 7 depending on
the limit you want to set. The chart shows the limits available.
Press AUX SET to confirm your selection and exit AUX SET mode,
or press MODE to continue setting other functions.
Temperature limits—Cool
0 = 60°F to 85°F
1 = 64°F to 85°F
2 = 66°F to 85°F
3 = 68°F to 85°F
4 = 70°F to 85°F
5 = 72°F to 85°F
6 = 74°F to 85°F
7 = 76°F to 85°F
MODE 6
Remote Thermostat – Class 2
The default setting for Mode 6 is OFF.
Setting this mode to ON will allow the unit to operate with a Class
2 Remote Control Wall Thermostat. Press MODE until a 6 appears
in the first digit of the display for Class 2 mode. Press the down
arrow to turn the option OFF "
option ON "
Press AUX SET to confirm your selection and exit AUX SET mode,
6
or press MODE to continue setting other functions.
All manuals and user guides at all-guides.com
" or the up arrow for ON "
." This is shown in the second digit of the
Temperature limits—Heat
0 = 60°F to 65°F
1 = 60°F to 70°F
2 = 60°F to 72°F
3 = 60°F to 74°F
4 = 60°F to 76°F
5 = 60°F to 78°F
6 = 60°F to 80°F
7 = 60°F to 85°F
." Press the up arrow to turn this
." This is shown in the second digit of the display.
Freeze Sentinel OFF
." This is shown
Freeze Sentinel ON
Heat Sentinel OFF
Heat Sentinel ON
" or the up
Constant
Fan OFF
Temperature Limiting Cool – Limit 2
Temperature Limiting Heat – Limit 3
Class 2 OFF
HIGH
COOL
LOW
FAN
AUTO
HEAT
HIGH
COOL
LOW
FAN
AUTO
HEAT
HIGH
COOL
LOW
FAN
AUTO
HEAT
HIGH
COOL
LOW
FAN
AUTO
HEAT
Constant
Fan ON
HIGH
COOL
LOW
FAN
AUTO
HEAT
HIGH
COOL
LOW
FAN
AUTO
HEAT
Class 2 ON

Publicité

loading

Ce manuel est également adapté pour:

Appliances zoneline 6100 serieAppliances zoneline az61h15ead