CAUTION
Repair, modification and inspection of HiKOKI Power
Tools must be carried out by an HiKOKI Authorized
Service Center.
This Parts List will be helpful if presented with the
tool to the HiKOKI Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools,
the safety regulations and standards prescribed in
each country must be observed.
MODIFICATIONS
HiKOKI Power Tools are constantly being improved
and modified to incorporate the latest technological
advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country specific regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling
instruction, to a HiKOKI Authorized Service Center.
NOTE
Due to HiKOKI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
IMPORTANT
Correct connection of the plug
The wires of the main lead are coloured in accordance
with the following code:
Blue: -Neutral
Brown: -Live
As the colours of the wires in the main lead of this tool
may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black. The wire
coloured brown must be connected to the terminal mark-
ed with the letter L or coloured red. Neither core must be
connected to the earth terminal.
NOTE
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not
be applicable to other markets except The United
Kingdom.
Information concerning airborne noise and vibration
The measured values were determined according to
EN 60745 and declared in accordance with ISO 4871.
G18 series
Measured A-weighted sound power level: 106 dB(A)
Measured A-weighted sound pressure level: 95 dB(A)
Uncertainty KpA: 3 dB(A)
Wear ear protection.
The typical weighted root mean square acceleration
2
value: 3.0 m/s
.
G23 series
Measured A-weighted sound power level: 101 dB(A)
Measured A-weighted sound pressure level: 90 dB(A)
Uncertainty KpA: 3 dB(A)
Wear ear protection.
The typical weighted root mean square acceleration
value: 4.5 m/s
2
.
Information about power supply system of nominal
voltage 230 V~ (For G18SE3, G18SG2, G23SC3,
G23SE2 only)
Under unfavorable mains conditions, this power tool may
cause transient voltage drops or interfering voltage
fluctuations .
This power tool is intended for the connection to a power
supply system with a maximum permissible system
impedance Z
of 0.23 Ohm at the interface point (power
MAX
service box) of the user's supply.
The user has to ensure that this power tool is connected
only to a power supply system which fulfills the
requirement above.
If necessary, the user can ask the public power supply
company for the system impedance at the interface
point.
English
10