Charger Protection
No.
Charger Protection
1
Over Voltage Protection
2
Under Voltage Protection
3
Overload Protection
Over Temperature
4
Protection
5
Ground Protection
6
Leakage Protection
13
Causes/Actions
Input is greater than 120%,
the relay is turned off
Input is less than 80%, the
relay is turned off
Output current is greater
than 110%, the relay is
turned off. The power needs
to be disconnected then
restored.
When the temperature on the
main board reaches 185°F,
the power will be reduced to
50%. Once it reaches 194°F
the power will turn off
completely
The ground wire is not
detected, or the ground wire
has become disconnected
during the charge cycle. The
relay is now disconnected
CCID –
(Charge Circuit
Interrupting
Device). A safety
device that will disable utility
power to the charger in the
event that a loss of isolation
is detected.
The relay is now
disconnected
WALL MOUNT BRACKETS
The Charging Station and gun can be mounted to a wall using the supplied mounting brackets:
1)
Wall socket
2)
Charging Station Plug
3)
Charging Station
4)
Charging Station Wall Mounting Bracket
5)
Gun Holder Mounting Bracket
6)
Charging Station Gun
WARNING:
The Charging Station must be installed in a well-ventilated dry space away from any
flammable substances, gas, or oil lines.
Always coil up the gun cable after use to prevent damage occurring to the cable or the
gun.