Microwave Motion Sensor
DIP Switch settings:
Daylight sensor (default disabled)
The sensor can be set to only allow the
luminaire to switch on when the ambient
lux-level is less than approximately 300[lux].
When set to DISABLE mode, the daylight
sensor will switch on the luminaire when
motion is detected, regardless of ambient
light level




(*) Recomended maximum mounting
9a
height for optimal sensor performance
Detection range
H=4.0m
10c
Ceiling mounting
 
 
 
  





9b

100%: ~ 5[m]
40%: ~ 2.1[m]
100%
40%
    
  
 
 


 
 

The sensor is designed to connect one load only.
Connecting more than one load may damage the sensor.
Detection area
(default 100%)
Detection area can be reduced
by selecting the combination
on the DIP switches to fit
precisely each application.
Detection radius: 4 - 9 [m]
Mounting height up to 4m (*)








H=2.5m
100%: ~ 7[m]
40%: ~ 3.7[m]
 
  
 


6/16
Hold time (default 5 min.)
Refers to the time period the
lamp remains on no motion
detected.




40%
100%
Wall mounting
    
  
   
 

 


 
 
 
