conds the pump will try to restore the fl ow.
Yellow Power ON and Red Failure are lit:
After approx. seconds without any fl ow the motor will switch off .
The dry running guard has tripped; it is no longer possible to draw
in the medium. Use the pump's operating manual to fi nd the cause
of the fault (e.g. a leaking intake line) and rectify it. Then restart the
pump by pressing the ON button (5) on the fl ow switch.
Yellow Power ON is blinking:
The pump is building up pressure (e.g. a water tap is closed) and
then switches off automatically.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged, it must be replaced
by the manufacturer or its after-sales service or similarly trained per-
sonnel to avoid danger.
8. Cleaning, maintenance and ordering of spare parts
The equipment is almost completely maintenance free. In order to
ensure a long service life, however, we recommend that you regularly
check and care for the product.
Danger!
The equipment must be disconnected from the power supply (pull
the power plug) prior to performing any maintenance.
8.1 Servicing
If the equipment becomes clogged, connect the discharge line to
the water line and disconnect the suction hose. Open the water
line. Switch on the equipment several times for approx. two se-
Anl_PE-HWA_630_SPK7.indb 143