6. Operation
Set up the pump on flat and firm ground.
Attach the intake line ready for use.
Unscrew the water filler screw (2) and remove the coarse filter (8)
together with the non-return valve (9) as shown in Figure 2. Now
you can fill the pump housing with water. Filling the intake line ac-
celerates the priming process.
Assemble in reverse order.
Plug into the mains.
Press the ON switch (5)
All shut-off devices in the pressure line (spray nozzles, valves
etc.) must be fully opened when priming so that any air in the in-
take line can escape.
Depending on the suction height and the amount of air in the in-
take line, priming can take anywhere between 30 seconds and
5 minutes. If it takes longer than this, the pump should be refilled
with water.
If the pump is removed again after use, it must always be refilled
with water whenever it is connected up and used again.
GB
Operating the fl ow switch:
The operating mode is indicated by the LEDs.
Yellow Power ON is lit:
The power cable is connected.
Yellow Power ON and Green Pump ON are lit:
The pump is in operation and starts up immediately; a consumer for
drawing off medium is open.
Yellow Power ON, Green Pump ON and Red
Failure are lit:
The pump is running dry without any medium. For approx. 30 se-
Anl_PE-HWA_630_SPK7.indb 142
Anl_PE-HWA_630_SPK7.indb 142