Removing a Repeater from a Panel
1. From the panel's Installer Menu,
Agility/WiComm: go to Programming > Radio Devices > Delete > Repeater
LightSYS Plus/LightSYS Air: go to Install > WL Device > Delete > Repeater
2. Delete the repeater without deleting devices enrolled to the repeater (1. Keep
Devices) or delete the repeater and move the devices to the panel (2. Devices →
Main).
3. Click <OK>.
NOTES:
1. When replacing the Serial number of an enrolled repeater with the Serial Number of
a new repeater, all assigned devices will move to the new repeater (as in option 1.
Keep Devices).
2. When exiting Installer Mode, the panel sends the updated list to the repeater.
Testing the System
When the devices, repeater and control panel have been placed in their final locations,
test the complete system, as follows:
1. Calibrate the repeater (for instructions, refer to the control panel's Installation
Manual).
2. Perform a walk test and observe the LEDS of the devices and the repeater (for
instructions refer to the device's User Guide).
The results of the RSSI are between the repeater and the allocated devices. For
successful communication, the strength of the signal of the device should be higher (by
at least 7%) than the calibration value of the repeater.
NOTE: The control panel may receive signals both from the repeater and directly from
devices (does not apply to keyfobs). The control panel will ignore messages that are
received directly from devices assigned to the repeater.