2.b
ALARM (According to the model)
1
Pump reference DE05NCA620 without alarm : the user will duly check
before installing the pump that a liquid overflow will be without
consequence of any kind for furnitures, various equipments, environment
and the security of the persons. In any case, the installation or the lack of
installation of a suitable alarm system will involve the sole responsibility of
the pump user.
There is a change-over contact with a maximum interrupting capacity of 5
Amperes resistive at 250 Vac and a minimum interrupting capacity of 10
mA at 5 VDC. Use the alarm to inform (sound signal) of any risk of
overflow (NO contact)
Cable with two conductors must be used.
Blue
Brown
The tank contains a float which controls the alarm.
If the water level attains the critical threshold, the alarm sends a signal
before the overflow,
SICCOM STRONGLY recommends connecting this relay contact intended
for power supply to the audio or light alarm.
Attention:
your interrupting capacity is limited to 5 A max (resistive).
OPERATION
®
SUNNY FLOWATCH
contains a pump and tank equipped with a float.
On condensation in the tank, the pump is activated.
a
3.
INSTALLATION
At first, fix the device horizontally to the wall with these two attachment
lugs.
With the help of a spirit level, adjust the positioning of the device
before any final attachment by using the screws and pins provided.
Provide easy access to the device for maintenance.
Then, during activation, pay attention that the device is protected against
humidity.
b
3.
COMMISSIONING
1) inlet connection
The device has an inlet of Ø 32 mm.
Connect the water inlet to this inlet.
If necessary, use a double adapter of Ø 32 mm.
2) outlet connection
Insert a hose of Ø 4x7 in the outlet.
Position the hose vertically and make a circular arc to avoid pinching
the hose.
It is then possible to connect the hose to another PVC hose of a larger
diameter.
3) Precautions before activation
Check the activation of the pump and record water evacuation by the
pump before switching it off.
Test the alarm by pouring water continuously, even after activation of
the pump so that the float may activate the alarm.
Do not operate the pump dry.
WARRANTY
7
Your pump is guaranteed to be in perfect condition when it leaves our factory. SICCOM SAS PRODUCTS ARE WARRANTED 2 YEARS (24 MONTHS) FROM
THE DATE OF INVOICE AGAINST DEFECTIVE MATERIALS AND WORKMANSHIP.
Customers not located in France should return prepaid the defective products to the nearest SICCOM SAS distributor
inspected and spotted through there original tracking code to determine the cause of failure before warranty is approved. If there are no apparent signs of
customer abuse and if the installation guidelines prove to have been duly respected, the product will be replaced or repaired.
DISCLAIMER :
Any implied warranties will be limited in duration to the express warranties given above. In any event, the liability of SICCOM SAS is solely limited to the
replacement or repair of the products supplied plus the freightage to the destination of the original delivery.
NEITHER SELLER NOR MANUFACTURER SHALL BE LIABLE FOR ANY INJURY, LOSS OR DAMAGE, DIRECT, INCIDENTAL OR CONSEQUENTIAL
(INCLUDING BUT NOT LIMITED TO INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS, LOST SALES, INJURY TO PERSON OR
PROPERTY OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS), ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCTS AND THE
USER AGREE THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT.
Warranty will be void if any of the following conditions are found :
- Sealed motor housing opened
- Product connected to voltage other than indicated
- Reservoir cable cut off
- Pump allowed to operate dry (no fluid supply)
- Pumps used to circulate anything other than condensate water
- Product abuse by customer
- Alarm not connected
Before using, the user shall determine the suitability of the product for the intended use, and
user assumes all risk and liability whatsoever in connection therewith.
SICCOM SAS reserves the right to modify all or part of the product without any prior notice.
CLEANING
4.a
CLEANING OF THE FILTER
®
SUNNY FLOWATCH
is equipped with an integrated filter
Its cleaning is very simple.
Remove the filter which is located behind the condensate inlet hose.
Clean the filter rinsing it with clear water to remove particles and put it
back in its place.
SECURITY FEATURES
5
Some basic rules to be complied with:
Use of the device by children or unauthorized persons without assistance
is prohibited.
• The device must not be touched when one is bare foot or with a wet
part of the body.
• Intervention, even for a simple cleaning operation, without cutting off
the general power supply of the installation, is prohibited.
• Safety or regulation devices must not be modified without
authorisation and indications of the device manufacturer.
• Electric cables exiting the device must not be pulled, twisted or
detached even if it is disconnected from the power supply network.
• Pointed objects must not be inserted through the intake grills.
• Access "cover" leading to internal components must not be opened.
• The packaging must not dispersed, abandoned or left within reach
of children as it can be a source of danger.
• This product must not be sold in countries different from those
envisaged by the standard and the technical documentation.
• Unadapted tools such as combination pliers or extension cords for
power supply to the device must not be used.
DIAGNOSTICS AND SOLUTIONS
6
Situations
Probable causes:
The pump
- is the plug and socket-
does not
outlet connected?
operate
- Was there a power
failure?
- Stuck float
-Blocked condensate inlet
hose
The pump
-Blocked condensate
does not
evacuation hose
discharge
-Blocked filter
No alarm
-Stuck float
signal
(according
to model)
.
All products returned will be fully
Actions
-Connect the plug and
socket-outlet
-Check the power supply
voltage.
-Clean the tank
-Clean the concerned
hose
-Clean the hose
-Clean the filter
-Clean the tank