NOTE:
• Make sure the filter is securely locked. Otherwise, it would loosen and cause
dangerous.
• When activated carbon filter attached, the suction power will be lowered.
BULB REPLACEMENT
Important :
LED LIGHTS:
• Switch the unit off and pull out the plug first.
• Wait until the light bulb is cooled down before replacement.
• Remove the front part with the aid of screwdriver.
• Pull out the LED light carefully and replace with the same type and rated LED light
(2*2W LSD-B1 LED light)
• Replace the front part back to the unit with screwdriver.
•
ILCOS D code for this lamp is: DBR-2/65-H-64
– LED modules, self- ballasted – round lamp
– Max wattage: 2 W
– Voltage range: AC 220-240V
– Dimensions:
The bulb must be replaced by the manufacturer, its
service agent or similarly qualified persons.
Always switch off the electricity supply before
carrying out any operations on the appliance. When
handling bulb, make sure it is completely cool down
before any direct contact to hands.
When handling globes hold with a cloth or gloves to
ensure perspiration does not come in contact with
the globe as this can reduce the life of the globe.
11