Chapter 3: Operating Instructions
3.2
Charging Indication
The following table describes the charging indications when the charger is in use.
Table 6: Charging Indication
LED Indication
Single Flash Green
Slow Flash Amber
Fast Flash Red
Steady Red
Slow Flash Green
Steady Green
Off
16
Charger Status
Charger successfully powered up and ready for use.
●
Pre-Charge: Battery under-voltage recovery.
●
Temperature < Approximately 5 °C (or Value Programmed in Bat-
tery): Wait to charge—battery too cold.
●
Temperature ≥ Approximately 45 °C (or Value Programmed in
Battery): Wait to charge—battery too hot.
●
Under-Voltage Recovery Timeout (15 Minutes)
●
Loss of Charge Current Control (Difference between Command
and Feedback > Electrical Tolerance Analysis)
●
Excessive Power Supply Voltage
●
Battery+ Open
●
Thermistor Short to Ground
●
Battery+ and Battery- Short
●
Faults
●
Fast Charge or Charge Ramp Down
●
Normal operation
●
Nearly Charged
●
Normal operation
●
The battery is charged to at least 90% of the threshold program-
med into the battery. Or, if the battery lacks an internal memory
device, the charging current has ramped down to a value less
than a charger default threshold.
●
Charged or Nearly Charged
●
Normal operation
●
The battery is charged to at least 95% threshold programmed into
the battery. Or, if the battery lacks an internal memory device, the
charging current has ramped down to a value less than a charger
default threshold.
●
Thermistor Open
●
No battery in pocket