EN
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is not
working
The appliance turns on,
but the temperature is too
high/low
The appliance is leaking
water
The appliance is unusually
loud
Technical Specifications
Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
Power
G590
250W
220-
G591
550W
240V~
GD879
800W
50Hz
GD880
870W
Note: For optimal product performance and efficiency, please ensure to mind the net usable capacity (load
limit) when filling.
8
G590-G591_GD879-GD880_ML_A5_v17_20240402.indb 8
G590-G591_GD879-GD880_ML_A5_v17_20240402.indb 8
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat source
or air flow to the condenser is being
interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being stored
in the appliance
Appliance is overloaded
The appliance is not properly levelled
The discharge outlet is blocked
Movement of water to the drain is
obstructed
The water container is damaged
The drip tray is overflowing
Loose nut/screw
The appliance has not been installed
in a level or stable position
Net usable
Current
Temp. Range
capacity
1.1A
-2°C ~ 5°C
1.1A
-10°C ~ -20°C
4A
-2°C ~ 5°C
5A
-10°C ~ -20°C
Check unit is plugged in correctly and switched on
Replace plug or lead
Replace the fuse
Check mains power supply
Defrost the appliance
Clean the Condenser
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a
cooler position
Remove any excessive hot foodstuffs or
blockages to the fan
Reduce the amount of food stored in the
appliance
Adjust the screw feet to level the appliance (if
applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Consult a qualified Technician
Empty the drip tray (if applicable)
Check and tighten all nuts and screws
Check installation position and change if
necessary
Gross
Volume
Refrigerant
(L)
(L)
313
440
R600a
313
440
R290
671
960
R290
671
960
R290
Solution
Dimensions
Weight
H x W x D mm
(kg)
1950 x 685 x 710
113
1950 x 685 x 710
113
2000 X 1340 x 710
165
2000 X 1340 x 710
165
2024/4/3 10:25