Connecting a module
When a module is connected, the performance of DMC 3000 are
extended:
•
to Hp(0,07) shallow measurement (*)
•
to Hp(10) neutron measurement (*)
•
to telemetry (long-distance radio transmission)
* A G3 protocol and V07.1.0 or newer firmware are required
The « measurement type » reports the current mea-
surement or the current alarm threshold.
•
H10 g: X+Gamma Hp(10)
•
H10 n: Neutron Hp(10)
•
H10 Tgn : total dose ((X+Gamma) + neutron Hp(10))
•
H.07 g: beta and X+Gamma Hp(0,07)
A module must always be connected and disconnected in pause.
To confirm module deconnection, it is necessary to remove the
battery of the DMC 3000 or to perform a « detach module »
operation using DMCUser software.
1
Remove the battery cover
3
Install the module
2
Equip your DMC 3000
with a 26-pin connector
4
Tighten the screws
- 17 -
The icon notifies
that the module is
connected.
Note: A 26-pin
connector is required
(ref. 00153458).