Horizontal Dimensional Data
2 ft [61 cm]
Alternate Service Access
Right return opposite side
FRONT VIEW
A
K
J
I
1.90 (4.8 cm)
Overall Cabinet
Horizontal
Model
A
B
C
Width Depth Height In
in.
22.5
53.0
19.3
024
cm. 57.2
134.6
49.0
in.
22.5
63.0
19.3
036
cm. 57.2 160.0
49.0
in.
25.6
72.0
21.3
048-
cm. 65.0 182.9
54.1
060
in.
25.6
77.0
21.3
072
cm. 65.0 195.6
54.1
* Dimensions shown are for left return side discharge other configurations shown in tables below
Condensate is 3/4" PVC female glue socket and is switchable from side to front
Unit shipped with 1" [25.4mm] return duct flanges suitable for duct connection.
Discharge flange is field installed and extends 1" [25.4mm] from cabinet
Water connections extend 1.2" [30.5mm] beyond front of cabinet.
The optional 1" filter rack (not shown) has the same return opening connection size as the duct flanges shown in the drawing. The filter rack
extends 2.25"(57.1 mm) from the unit.
The optional 1" filter rack is suitable for duct connection.
The optional filter rails (not shown) extend 1.25" (31.75 mm) from cabinet.
The 024 model is not field convertible changing from end to side discharge. It requires an additional discharge panel (not supplied).
024 Model
L
in
2.2
Right Return End
Discharge
cm
5.6
14.5
in
6.9
Right Return Side
Discharge
cm
17.5
in
6.5
Left Return End
Discharge
cm 16.5 18.5
2 ft [61 cm]
Primary Service Access
G
F
E
D
1.90 (4.8 cm)
Water Connections
D
E
F
G
H
HWG
HWG
Cond-
Out
In
Out
ensate
2.3 5.3
13.8 16.8
0.8
5.8 13.5 35.1 42.7
2.0
2.3
7.3
13.5 16.5
0.8
5.8 18.5 34.3 41.9
2.0
2.3
7.3
15.9 18.9
0.8
5.8 18.5 40.4 48.0
2.0
2.3
7.3
15.9 18.9
0.8
5.8 18.5 40.4 48.0
2.0
O
036 Model
5.7
in
Right Return
End Discharge
cm
16.5
8.3
in
Right Return
Side Discharge
21.1
cm
7.3
in
Left Return End
Discharge
cm
16.5
DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE
TOP VIEW
SIDE DISCHARGE VIEW
B
Electrical
Connections
I
J
3/4"
1/2"
Loop
cond
cond
cond
HWG
Water
Power
Ext
(O.D.)
FPT
Supply
Pump
Votage
1"
1/2"
8.9
11.5
Swivel
stub
22.6
29.2
1"
1/2"
9.5
12.1
Swivel
stub
24.1
30.7
1"
1/2"
9.5
12.1
Swivel
stub
24.1
30.7
1"
1/2"
9.5
12.1
Swivel
stub
24.1
30.7
L
O
048-060 Models
6.5
6.6
Right Return
End Discharge
16.8
2.3
5.7
Right Return
Side Discharge
5.8
14.5
6.5
6.6
Left Return End
Discharge
16.8
19
Q
P
2.00 5.1
Mount (2) hanger brackets
as shown to allow access
to filter
L
L
N
O
M
C
H
Discharge Connection
Duct Flange Installed
K
1/2"
L*
M
N
O*
Low
Supply
Supply
Height
Depth
13.7
1.7
10.5
9.5
8.2
34.8
4.3
26.7
24.1
20.8 5.6
14.3
2.3
10.5
9.5
5.7
36.3
5.8
26.7
24.1
14.5
14.3
1.9
13.6
13.2
5.0
36.3
4.8
34.5
33.5
12.7 7.4
14.3
1.9
13.6
13.2
5.0
36.3
4.8
34.5
33.5
12.7
L
O
072 Model
in
1.9
5.0
Right Return
End Discharge
cm 4.8
12.7
in
5.7
5.0
Right Return
Side Discharge
cm 14.5 12.7
in
5.7
4.9
Left Return End
Discharge
cm 14.5 12.4
END VIEW
S
O
R
Return Connection
Return Duct Flanges
P
Q
R
S
Return
Return
Depth
Height
2.2
21.8
16.5
1.5
55.4
41.9
3.8
2.8
30.5
16.7
1.3
7.1
77.5
42.4
3.3
2.9
35.5
18.6
1.3
90.2
47.2
3.3
2.8
40.4
18.7
1.5
7.1
102.6
47.5
3.8
7/17/14
L
O
in
1.9
5.0
cm
4.8
12.7
in
5.7
5.0
cm
14.5
12.7
in
5.7
5.0
cm
14.5
12.7