Specifications
Model
Series
Nominal voltage(s) and
range
Nominal input
frequency and
tolerance
Nominal output voltage
Nominal output
frequency
Output voltage
regulation in line mode
Output voltage
regulation in battery
mode
Nominal output power
in W / VA
Output voltage
waveform
Maximum output
current @ P . F.
Efficiency with nominal
load
Maximum operating
altitude at 100% of
nominal power
Online Overload
Capability
Overload capacity in
battery mode
Current limitation
Autonomy time at full
load
Battery recharge time
Typical transfer time
Outlets
Maximum input current
SMART1500LCDTXL
AG-06B6
120V~, 89-145V
50/60 Hz (+/- 5 Hz)
120V~ in line mode
and 120V~ battery
50/60 Hz (+/- 0.5 Hz)
120V~
(+10% / -13%)
120V~ (+/-10%)
1200W / 1440VA
Sinusoidal in line mode
and quasi-sine (PWM)
in battery mode
12A @ 120V~
P .F. = 0.83
98.4%
6562 ft.
(2000 m) above the
sea level
110%+/-10% @
5 min.; 120%+/-10%
immediately to Fault
mode
110%+/-10% @
5 seconds; 120%+/-
10% immediate
shutdown
Input 12A
1.5 minutes @
1200W; 10 minutes
@ 900W w/external
battery
8 hours
6 milliseconds
(10 milliseconds max.)
6x 5-15R outlets
with battery backup,
regulation and surge;
2x 5-15R with surge-
only
12A
12
SMART1500TSU
AG-06B4
120V~, 89-145V
50/60 Hz (+/- 5 Hz)
120V~ in line mode
and 120V~ battery
50/60 Hz (+/- 0.5 Hz)
120V~
(+10% / -13%)
120V~ (+/-10%)
1200W / 1440VA
Sinusoidal in line mode
and quasi-sine (PWM)
in battery mode
12A @ 120V~
P .F. = 0.83
98.4%
6562 ft.
(2000 m) above the
sea level
110%+/-10% @
5 min.; 120%+/-10%
immediately to Fault
mode
110%+/-10% @
5 seconds; 120%+/-
10% immediate
shutdown
Input 12A
1.5 minutes @ 1200W
8 hours
6 milliseconds
(10 milliseconds max.)
6x 5-15R outlets
with battery backup,
regulation and surge;
2x 5-15R with surge-
only
12A
OMNIVS1500XL
AG-06B5
120V~, 89-145V
50/60 Hz (+/- 5 Hz)
120V~ in line mode
and 120V~ battery
50/60 Hz (+/- 0.5 Hz)
120V~
(+10% / -13%)
120V~ (+/-10%)
940W / 1440VA
Sinusoidal in line mode
and quasi-sine (PWM)
in battery mode
12A @ 120V~
P .F. = 0.65
98.4%
6562 ft.
(2000 m) above the
sea level
110%+/-10% @
5 min.; 120%+/-10%
immediately to Fault
mode
110%+/-10% @
5 seconds; 120%+/-
10% immediate
shutdown
Input 12A
3 minutes @ 940W;
11 minutes @ 940W
w/external battery
8 hours
6 milliseconds
(10 milliseconds max.)
6x 5-15R outlets
with battery backup,
regulation and surge;
2x 5-15R with surge-
only
12A

Publicité