TROUBLESHOOTING PROCEDURES FOR BREEZE I AND BREEZE II
Issue
Cause
After installation,
1. The power source is not turned ON.
the unit doesn't
work.
2. The power line and the cable locking connector
is not connecting properly.
3. The switch or control board wirings are
disconnected.
4. The wires on control board or switch are loose.
5. The switch or control board is defective.
Light works, but
1. The blower is defective, possible seized.
blower is not
2. The thermally protected system detects if the
turning.
blower is too hot to operate and shuts the blower
down.
3. Damaged capacitor.
4. The control board or blower switch is defective.
The unit is
1. The blower is not secure in place.
vibrating.
2. Damaged blower wheel.
3. The hood is not secured in place.
The unit is
whistling.
2. The duct pipe connections are not sealed or
connected properly.
The blower is
1. Defective bulb.
working, but the
2. The light bulb is loose.
lights are not.
3. The light bulb plug is disconnected.
The hood is
1. The hood might be hanging to high from the
not venting out
cook top.
properly.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the
ventilation of the hood.
3. Blockage in the duct opening or duct work.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting.
Mesh Filter is
vibrating.
2. Filter sping clip is broken.
What to do
1. Make sure the circuit breaker and the unit's
power is ON.
2. Check the power connection with the unit is
connected properly.
3. Make sure the wirings at the switch or control
board are connected properly.
4. Make sure the wires on the control board or
switch are connected properly.
5. Change the switch or control board.
1. Change the blower.
2. The blower will function properly after the
thermally protected system cool down.
3. Change the capacitor.
4. Change the control board or blower switch.
1. Tighten the blower in place.
2. Change the blower wheel.
3. Check the installation of the hood.
2. Check the duct pipe connections to be sure all
connections are sealed properly.
1. Change the bulb.
2. Tighten the light bulb.
3. Connect the light bulb plug.
1. Adjust the distance between the cook top and
the bottom of the hood within 24" and 32"
range.
2. Close all the windows and doors to eliminate
3. Remove all the blocking from the duct work or
duct opening.
5. Change the ducting to correct size.
1. Make sure the metal clips in the handle are
17