17. LED light warning signals (Fig. 23)
This product features functions that are designed
to protect the tool itself as well as the battery. While
the switch is pulled, if any of the safeguard functions
activate during operation, the LED light will blink as
described in Table 8. When any of the safeguard
functions are triggered, immediately remove your
fi nger from the switch and follow the instructions
described under corrective action.
Safeguard Function
Overburden Protection
Reactive Force Control
Temperature Protection
OPERATIONAL CAUTIONS
Resting the unit after continuous work
(1) The power tool is equipped with a temperature
protection circuit to protect the motor.
Continuous bolt-tightening work may cause the
temperature of the unit to rise, activating the
temperature protection circuit and automatically
stopping operation.
If this happens, allow the power tool to cool before
resuming use.
(2) After use for continuous tightening wood screw works,
rest the unit for 15 minutes or so when replacing the
battery. The temperature of the motor, switch, etc.,
will rise if the work is started again immediately after
battery replacement, eventually resulting in burnout.
LED Light Display
On 0.1 second/off 0.1 second
On 0.5 second/off 0.5 second
Table 8
If the operating with the shift knob set on
HIGH, adjust to LOW and continue operation.
Remove the cause of the overburdening.
Remove the cause of the overburdening.
When operating the tool, fi rmly hold the tool
to make sure it doesn't jerk.
Allow the tool and battery to thoroughly cool.
English
Fig. 23
Corrective Action
19