Firing in transitional periods
When the Stove is operated in a transitional period (when outdoor temperature exceed 15° C) it may
happen that the chimney has no underpressure (no draft). In that case try to get the required
underpressure by stoking the chimney. If you fail in that attempt, we would advise you to give up firing.
While setting fire, it is useful to open the windows of the room for equalization of indoor and outdoor air
pressure.
Maintenance and cleaning of the Stove
After each heating season the Stove, the flue gas pipes and the chimney should be cleaned of soot
deposits. Neglect of regular checks and cleaning increases the risk of fire in the chimney. If fire breaks
out in the chimney, take the following steps:
• do not use water to extinguish fire
• close all stove and chimney air inlets
• when the fire is put out, call your chimney sweeper to inspect the chimney
• call the dealer's maintenance service to inspect the stove
The door glass can be cleaned with standard window cleaning agents.
Should any irregularities occur during the operation of the Stove (such as smoking), contact your
chimney sweeper or the nearest maintenance service. Any repair works on the Stove may be done
only by authorized persons and only original spare parts may be installed in it.,
It's used for cleaning enamel and painted parts using soap and water, non-abrasive or chemically non-
aggressive detergents.
Warranty
The Warranty applies only if the Stove is used in accordance with these Technical Instructions.
Space heating capacity
The size of the heated space depends on the heating mode and the thermal insulation of the
space.
For heating with a 9 kW source, it is possible, depending on the heating conditions, to heat:
Occasional or intermittent heating should be considered as less favorable or even unfavorable
heating conditions.
The choice of the chimney
The chimney size is subject to DIN 4705, with the following data being applicable:
Nominal output [kW]
Flue gas mass flow (m)
Flue gas mean temperature behind the flue gas extension
Minimum chimney underpressure [p] at nominal thermal output
Minimum chimney underpressure [p] at 0.8-fold nominal output
in favourable conditions
in less favorable conditions
in unfavorable conditions
21
160 m³
105 m³
75 m³
9
8,2
268
0,12
0,10
kW
g/s
°C
mbar
mbar