Télécharger Imprimer la page

Plamen Vesta Directives Techniques page 20

Publicité

Power is adjusted by means of the primary air controller on the stove door.
Secondary air is brought above the glass, sufficient for cleaning the glass. With a good chimney
and quality dry wood that air will do to achieve nominal power of 9 kW.
The Stove's power also depends on the underpressure in the chimney (its draft). If the
underpressure in the chimney is excessively high, we would advise you to reduce it by means of
a flap installed in the flue gas pipe.
The correct use of the air controller also requires some experience. Make use of our
recommendations about the easiest way to operate your Stove.
Adjusting the controller for setting fire and some time thereafter, Figure 2.
Once the fire is strong enough and sufficient quantity of embers, return the controller to the
position required for the Stove to develop the amount of heat you need.
By adding 3 to 4 kg of fuel and keeping the controller at the maximum, the Stove's power will
reach 11-12 kW.
The position of the controller for 9 kW nominal power:
Figure 3 – when fired with wood
Figure 4 – when fired with wood briquettes
For minimum power, close completely the primary air controller, Figure 5, and close the flap
installed in the flue gas pipe, if available.
Add fuel only as much as needed for fire maintenance.
20

Publicité

loading