Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain condensate from
valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a properly sized Safety Air Fuse
upstream of hose and use an anti-whip device across any hose coupling without internal shut-off, to prevent
hose whipping if a hose fails or coupling disconnects. See drawing 04581666 and table on page 2.
Maintenance frequency is shown in circular arrow and defined as h=hours, d=days, and m=months. Items
identified as:
1.
Air filter
2.
Regulator
3.
Lubricator
4.
Emergency shut-off valve
5.
Hose diameter
6.
Thread size
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled, degreased and parts
be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll-Rand Office or Distributor.
EN-2
Sound Level dB (A)
(ISO15744)
Pressure (L
)
p
"K
"=3dB(A)
pA
99
99
94
94
93
93
7.
8.
9.
10. Grease - during assembly
11. Grease - through fitting
Power (L
)
w
"K
"=3dB(A)
wA
110
110
105
105
104
104
Coupling
Safety Air Fuse
Oil
Vibrations Level
(ISO8662)
m/s²
5.2
5.2
5.2
5.2
5.5
5.5