TROUBLE SHOOTING
Trouble
No response from
fixture when power
is applies
Fixture resets but
does not respond
correctly to
controller (DMX
mode operation)
Colours cannot be
mixed
Fixture does not
reset correctly
No light, lamp cuts
out intermittently, or
burns out too
quickly
TECHNICAL SPECIFICATION / TECNISCHE SPECIFICATIE / TECHNISCHE DATEN
/ ESPECIFICACIONES TÉCNICAS / SPÉCIFICATIONS TECHNIQUES /
SPECYFIKACJA TECHNICZNA
Rated voltage
Rated power
LED
Beam angle
Pan movement
Tilt movement
Strobe
DMX Channels
Function
Dimensions per unit
Weight (per unit)
The specifications are typical. The actual values can slightly change from one unit to the other. Specifications can
be changed without prior notice.
Probable cause(s)
No power to fixture
Primary fuse blown
Secondary fuse blown
Controller not connected
Incorrect addressing of the
fixtures
Bad data link connection
Conflict between tracking
and vector control
Data link not terminated
Defective fixture or 2
devices transmitting on link
Random colour mixing is
on
Electronic or mechanical
failure
Lamp missing or blown
Fixture or lamp is too hot
: AC1100~240V 50/60Hz
: 85 W
: 60W RGBW 4-in-1
: 4°
: 540°
: 220°
: 1-10 times/second
: 14 Channels
: DMX, Auto, Sound active, Manual and Master-Slave.
: 205 x 190 x 290mm
: 4.2 kg
Remedy
Check power cables
Replace fuse
Replace fuse
Connect controller
Check address setting on fixture and controller
Inspect cables and correct poor connections and/or broken
cables.
Eliminate scene cross-fade on controller
Insert termination plug in output of last fixture
Bypass fixtures one at a time until normal operation is
regained: unplug both connectors and connect them
directly together
Turn off random colour mixing
Contact service technician
Disconnect fixture and replace lamp
Allow fixture to cool. If problem persists, contact service
technician