Chapter 3.) A maximum of two other fires can be connected to the chimney to be
For safety reasons it is not permitted to use a steam extractor hood to remove air
when the stove is producing heat.
2.5 Outside air intake
Oxygen or air is constantly required for the combustion process. As a rule, the air
available in the installation room is sufficient (see also Chapter 2.2).
With well-sealed windows and doors, the presence of mechanical ventilation (e.g.
kitchen or bathroom) or other fireplaces (including gas boilers) in the apartment, the
proper air supply can be severely disturbed. If this is the case, it is possible to supply
the combustion air directly from outside or from another, sufficiently ventilated room
(e.g. basement).
For this purpose, the wood-burning stoves offer a central air intake nozzle Ø 100 mm
on the back as standard, which must be installed.
Only smooth pipes with a minimum diameter of
100 mm can be used. The air line should also have a shut-off valve near the furnace.
The position "open" - "closed" must be clearly marked on the butterfly valve and must
be carried out correctly. Among other things, arches must have inspection openings
for the chimney sweep and be properly insulated against condensation. The line
should not be longer than 4 m and not have more than 3 bends. If the line leads out-
doors, it should be provided with a suitable windbreak and fly screen.
General information on the subject of room air dependent or room air inde-
pendent operation:
The stove is supplied as a standard room air-dependent fireplace stove. This means
that the stove draws all of the combustion air from the installation room via the central
air intake on the back. A sufficient supply of combustion air (at full load approx. 25m³ /
h) is absolutely necessary.
In combination with ventilation and air conditioning systems (e.g. controlled ventilation
systems, fume hoods, etc.), Section 4 of the Firing Ordinance (FeuVO) is decisive in
Germany. The flue gas routing must be monitored by special safety devices (e.g. via
an approved differential pressure monitor) or, if a ventilation system is used, this must
connected to the stove.
The fire-place can usually be jointed
to the chimney with an arch.
With weak chimney draught, the
fireplace is to be connected to the
chimney through a vertical flue gas
pipe facilitating discharge.