INTERPRETING THE TEST INDICATOR LEDS
- When the energiser is working correctly the central green LED of the energizer lights up with each fence pulse.
- If the left-hand blue LED is on, then the fence has significant parallel losses. This means that there is probably a large amount of
vegetation growth in contact with the fence and/or faulty insulators, or that you are testing the quality of the earth connection according to
the procedure described before) You should plan to clear the vegetation around the fence and check the installation in the near future.
- If the blue LED is on and the green LED is off, then the parallel loss on the fencing is high and there is too much vegetation in contact with
the fence line and/or faulty insulators. You must clear the vegetation around the fence and check the installation.
- If the red LED is on (only if a return earth rod has been installed), the earth stake quality needs to be improved according to the steps
detailed in paragraph 5 before
CAUTION : Once the plug is connected to the mains power supply, the central green LED that indicates correct functioning must light up
approximately 50 times per minute.
V
BARGRAPH :
max
- This shows the state of the general voltage on the energiser terminals.
Delayed effect fence energiser.
DELAYED EFFECT :
- For your safety, the device adapts its output energy to a charge change after 25 seconds.
- The device can also enter into safety mode. When there is a sudden and considerable increase in charge to the fence, the
unit emits a noise, the warning light flashes, and the frequency of the pulses and the output energy are decreased.
Safety mode lasts for 12 minutes. During this time, the device continues to supply enough energy to correctly contain animals.
The digital display alternates between 2 screens.
1st screen :
2nd screen :
Example of an average
amount of vegetation
Low vegetation
- When the energizer is in safety mode or delayed effect (see above information), the symbol
UBI 15 000 / V150 - DISPLAY :
x,x joules
x,x volts
VEGETATION
VEGETATION
(a)
(b)
(c)
Output Energy
Output Voltage
Indicates the amount of vegetation touching the fence.
Heavy vegetation
9
VEGETATION
will be displayed.