REAR PANEL
Positive (+) DC
Input Terminal
Mounting
Points
•
Positive Terminal — Positive (+) DC Input (Red)
•
Negative Terminal — Negative (−) DC Input (Black)
•
Cooling Fans — High-speed and load controlled
•
Ground Terminal — For attaching an insulated safety ground wire. This
safety wire is for protecting personnel if there is an unlikely failure in either
the cabling or enclosure insulation. Grounding the inverter enclosure
ensures personnel safety should a DC cable problem occur. During the
installation procedure, the Ground Terminal is connected either to a vehicle
chassis or to the negative DC terminal of the battery. Do not directly
connect this ground connection to the negative DC terminal of the inverter.
Use an insulated 10 gauge wire to make the ground connection. If the
inverter installation is located in fixed location, the safety wire can be
connected to earth's ground.
Wagan Tech and wagan.com are trademarks of Wagan Corporation.
User's Manual—Read before using this equipment
Terminal
Cover
©2019 Wagan Corporation. All Rights Reserved.
Negative (–) DC
Input Terminal
High Speed
Cooling Fans
Ground
Terminal
6