Pure Line 2000 by Wagan Tech
TROUBLESHOOTING
PROBLEM: Low or No Output Voltage – Fault LED Lit
Reason
Poor contact with battery, inverter
terminals.
PROBLEM: Inverter Auto Shut Down – Fault LED Lit
Reason
Battery voltage is below 10.0 volts.
Inverter is too hot (thermal shut down
mode).
PROBLEM: Inverter Shut Down – Fault LED Lit
Reason
Equipment being operated draws too
much power.
PROBLEM: Inverter Shut Down – Yellow LED Lit
Reason
GFCI Tripped.
15
®
Solution
Clean terminals thoroughly. Reinstall
and tighten.
Solution
Charge or replace battery.
•
Allow inverter to cool.
•
Check for adequate ventilation.
•
Reduce the load on the inverter to
the specified TrueRated
max output.
Solution
Do not use the equipment with this
inverter; use a higher wattage inverter.
Solution
Disconnect appliances. To reset, turn off
ON/OFF switch and turn back on.
www.wagan.com