FRONT PANEL
ON/OFF/
Remote
Switch
•
ON/OFF Switch — This switch controls AC output of the inverter.
•
Power LED (Green) — When this green LED is lit, the inverter is operating
normally.
•
Ground Fault LED (Yellow) — When the yellow LED is lit, the ground fault
circuit has been interrupted. Shut down the inverter and restart.
•
Fault LED (Red) — The RED indicator turns on as the inverter shuts down due
to overheating, overload, under voltage, or over voltage.
Immediately turn off all AC appliances if the FAULT LED is lit. Allow the
inverter to cool before continuing. Make sure that the ventilation vents
are not blocked.
If an inverter shutdown was preceded by a buzzing sound, there may
be an excessive load in combination with a low voltage or cable
problem.
Wagan Tech and wagan.com are trademarks of Wagan Corporation.
User's Manual—Read before using this equipment
Power LED
Ground Fault LED
Fault LED
2.1A
USB Port
Remote ON/OFF
Switch Connection
©2019 Wagan Corporation. All Rights Reserved.
High Output
Terminals
Three 115V
AC Outlets
4