4-17. Setting Internal DIP Switches On Motor Boards
Right Side Motor
Control Board PC1
Run-In Enabled
(Factory Default)
S1-1
Run-In feature is available.
X - Means switch may be in either
position.
.
If 14 pin power cable from pow-
er source does not provide volt-
age and current feedback, Run-
In will automatically disable.
OM-230 300 Page 20
Left Side Motor
Control Board
PC101
P1
Position Settings And Results For DIP Switch S1 On PC1, 101
Run-In Disabled
S1-1
Run-In feature is not avail-
able. X - Means switch may
be in either position.
Factory Set Default Set-
tings For DIP Switch S1
1
.
In the DIP switch S1 illustrations,
the elevated slider on each switch
is shown in white. For example,
the switches above are in the Off
position.
Automatic Run-In
(Factory Default)
S1-1 And S1-2
Run-In speed is approxi-
mately 1/2 weld wire feed
speed.
Remove wrapper.
1
DIP Switch S1 On Motor
Boards PC1 and PC101.
S1-1
Run-In enable or disable.
S1-2
Automatic Run-In versus Manual
Adjustment Run-in.
Install wrapper when finished.
Tools Needed:
1/4 in
Manually Adjusted Run-In
S1-1 And S1-2
Run-In speed is set using poten-
tiometer P1 located on Motor
Board PC1, 101.
.
P1 is a 25 turn potentiometer.
803 063 / Ref. 802 944