4-7. Control Box Connections
4-8. 14-Pin Plug Information
J
J
A
A
K
K
I
B
L
L
H
N
C
M
M
G
G
D
D
F
F
E
E
*The remaining pins are not used.
1
Pin*
A
24 volts ac with respect to socket G.
B
Contact closure to A completes 24 volts ac contactor control circuit.
G
Circuit common for 24 volts ac circuit.
C
+10 volts dc input from power source to wire feeder with respect to socket D.
D
Remote control circuit common.
E
0 to +10 volts dc output signal from wire feeder to power source with respect to socket D.
H
Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.