8. Activate the Timestrip
sensor by pressing the button on the
®
front of the filter.
A
A. Timestrip
9. Insert the filter back into the Duct-Free Filter housing so that
the Timestrip
sensor can be seen through the opening in
®
the front of the filter housing when the cabinet door is
opened.
10. Close the filter access door and close the latches attached
to the top of the blower transition.
View of Completed Installation
A. Front of cabinet
B. Exhaust airflow
8
sensor
®
A
B

Check Operation

1. Turn the downdraft system on Hi and verify the following:
Determine that there is airflow coming out through the
toe-kick area.
Determine that there are no air leaks around the flex hose
clamps.
2. Follow the instructions on the Flow Test Card provided with
the kit to verify the installation.

Filter System Care

The Duct-Free Filter System is designed to require minimal
attention between filter changes.
The filter is designed to last 6 months after the Timestrip
is activated. Verify the Timestrip
The housing can be cleaned with a paper towel and household
cleaners or with a cloth and warm soapy water. No special
cleaners are required.

TROUBLESHOOTING

No airflow through the system out through the
toe-kick area of the cabinet
For gas installation:
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Is the power supply cord to the cooktop unplugged?
Plug the power cord from the cooktop into a grounded
3 prong outlet.
For electric installation:
Is the power supply breaker tripped or the fuse blown?
Reset the breaker or replace the fuse.
The downdraft blower attached to the cooktop creates the
air flow that flows down through the Duct-Free system. If no
power is supplied to the cooktop, the system will not work.
Is the Timestrip
sensor window red?
®
Replace the filter.
Has the plastic bag been removed from the filter?
Remove and dispose of/recycle the plastic bag.
Is the Duct-Free Filter housing door shut, and are the
door latches closed?
Firmly close the filter housing door and door latches.