WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
�re, or electrical shock.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Pressing TEST (listen for click) button will trip and cut all
power to air conditioner.
3. Press and release RESET (listen for click; Reset button will
latch). The power supply cord is ready for operation.
INSTALLATION INSTRUCTIONS
Prepare Air Conditioner for Installation
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
1.
Unpack the Air Conditioner
Remove Packaging Materials:
Handle the air conditioner gently while unpacking the unit.
■
Cut the 4 plastic bands that secure the carton.
■
Remove the carton top and lift the air conditioner from the
■
base pad.
Remove tape and glue residue from surfaces before turning
■
on the air conditioner. Rub a small amount of liquid dish soap
over the adhesive with your fingers. Wipe with a damp cloth
and dry.
NOTES:
The Reset button must be pushed in for proper operation.
■
The power supply cord must be replaced if it fails to trip when
■
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch. The
■
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new
■
power supply cord obtained from the product manufacturer
and must not be repaired.
The power supply cord contains no user-serviceable parts.
■
Opening the tamper-resistant case voids all warranty and
performance claims.
Do not use sharp instruments, rubbing alcohol, flammable
■
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
Remove any packaging materials inserted into the side
■
louvers.
Dispose of/recycle packaging materials in an appropriate way.
■
2.
Install top channel
1. Place the top channel on the top of the air conditioner, lining
up the holes in the top channel with the holes in the top of the
air conditioner.
2. Using four
⁄
" screws, attach the top channel to the air
3
8
conditioner.
5