Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it down for longer than
three seconds. The system does not detect a potential malfunction of the battery due to misuse, for
example battery dropped or pierced, external heat damage, etc.
Status
All LEDs show in sequence, followed by one (1)
LED showing constantly green.
All LEDs show in sequence, followed by one (1)
LED quick-flashing yellow.
All LEDs show in sequence, followed by one (1)
LED showing constantly red.
Technical data
Product generation
Weight without battery
Single impact energy in accordance with EPTA procedure 05
Drilling diameter range in concrete/masonry (hammer
drilling)
Drilling diameter range in concrete/masonry (hammer
drilling)
Storage temperature
Ambient temperature for operation
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
Preparations at the workplace
WARNING
Risk of injury by inadvertent starting!
▶
Before inserting the battery, make sure that the product is switched off.
▶
Remove the battery before making any adjustments to the power tool or before changing
accessories.
8
Meaning
The battery can remain in use.
The check to ascertain the battery's state of
health did not complete. Repeat the procedure,
or consult Hilti Service.
If a connected product can still be used, the
remaining battery capacity is below 50 %.
If a connected product can no longer be used,
the battery has reached the end of its useful life
and has to be replaced. Consult Hilti Service.
TE 5-22
01
2.7 kg
(6.0 lb)
2.5 J
4 mm ... 28 mm
4 mm ... 28 mm
(0.2 in ... 1.1 in)
−20 ℃ ... 70 ℃
(−4 ℉ ... 158 ℉)
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
21.6 V
See the end of these operating in-
structions
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 40 ℃
(−4 ℉ ... 104 ℉)
−10 ℃ ... 45 ℃
(14 ℉ ... 113 ℉)
2351801
*2351801*