CODE
POSSIBlE CAUSE
Pump oil is low
16
17
Carbon build-up in pump.
18
Detergent type oil being
used in pump
19
Motor overload protection
switch has tripped
Extension cord is wrong
20
length or gauge
21
Loose electrical
connections
Possible defective motor or
22
starting capacitor
Paint spray on internal
23
motor parts
24
Fuse blown, circuit breaker
tripped
Tank pressure exceeds
25
pressure switch cut-in
pressure
26
Pressure release valve on
pressure switch has not
unloaded head pressure
POSSIBlE SOlUTION
Add ISO 100/SAE40, nondetergent, premium air
compressor oil to pump. See Compressor Pump
Oil under Maintenance.
Contact an authorized service center.
Drain oil and refill pump with ISO 100/SAE40,
non-detergent, premium air compressor oil.
See Motor Overload under Features.
Check for proper gauge wire and cord length.
See Extension Cords under Installation.
Contact an authorized service center.
Contact an authorized service center.
Contact an authorized service center. Do not
operate the compressor in the paint spray area.
See flammable vapor warning.
1. Check fuse box for blown fuse and replace
as necessary. Reset circuit breaker. Do not
use a fuse or circuit breaker with higher
rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay
fuse.
3. Check for low voltage conditions and/or
proper extension cord.
4. Disconnect the other electrical appliances
from circuit or operate the compressor on
its own branch circuit.
Motor will start automatically when tank
pressure drops below cut-in pressure of
pressure switch.
Set the On/Off switch to OFF. If the valve does
not open, replace switch. Contact an authorized
service center.
20