- The boiler return tap D must obligatorily remain open, even in the
case of the SUMMER SETTING in order to allow expansion of the
fluid in the circuit so as to avoid any damage to the device.
Appliance carrying this symbol must never be disposed of with
household waste, but must be collected separately for recycling.
At the end of their life, products must be collected and recycled
according to local regulations and ordinances.
When an appliance is installed at a higher altitude, the air out-
put temperature rises (around 10° C per 1000 m rise in ground).
The device you have just purchased was submitted to many tests and checks ensuring its quality.
We thank you for your choice and trust.We hope you will be fully satisfied.
A few recommendations:
Read the instructions before installing the device.
Power the device off before intervening on it, and check the power supply voltage.
Store the instructions, even after installing the device.
1) Location of the device
- This device was designed to be installed in residential premises. In any other case, please call your
distributor.
- Installation must comply with the standards currently enforced in the country of use.
- Locate the heater within minimum distances from obstacles. Do not install the device :
• In a draft likely to affect its control (under centralised mechanical ventilation, etc...).
• Under a fixed mains outlet.
• Inside zones 0 and 1 in bathrooms.
The device is to be installed so that switches and other
controls cannot be touched by a person in the bath or sho-
wer, except in the UK where IEE Regulations 701.512.2 and
701.512.3 apply. These allow the use of IP24 rated products
and their integral controls in Zone 2 and ouside zones.
Volume
3
I
NSTALLING THE DEVICE
Volume
Volume
2
1
17
GB
150 mm mini
150 mm mini
200 mm mini