V1.0
Not enough
pressure
Pump has pressure
but load is moving
Cylinder returns
itself
Cylinder cannot
return
Flow is too low
Visit www.princessauto.com for more information
Pneumatic/Hydraulic Foot Pump
1.
Air pressure too low
2.
Internal overflow
valve setting too
low
3.
System is leaking
Load exceeds the capacity
of the pump
System is leaking
1.
Oil return or joint is
blocked
2.
No load in the
cylinder
3.
Backspring broken
1.
Reservoir not
exhausting
2.
Air supply
insufficient
3.
Dirty filter
4.
Intake filter blocked
1.
Increase appropriately
(see Specifications)
2.
Adjust as needed
3.
Check all components and
accessories for leaks,
repairing or replacing as
needed
Reduce load
Check all components and
accessories for leaks, repairing
or replacing as needed
1.
Inspect and adjust as
needed
2.
Adjust
3.
Inspect and replace as
needed
1.
Ensure screw is loosened
to exhaust
2.
Increase appropriately
(see Specifications)
3.
Clean
4.
Clean
9258765
11