9258765
CLEARING THE AIR INLET FILTER
DISPOSAL
IMPORTANT! DO NOT pollute the environment by allowing
uncontrolled discharge of waste oil.
TROUBLESHOOTING
Problem(s)
Pressure building
slow under load
Pump has no
pressure
10
Pneumatic/Hydraulic Foot Pump
Possible Cause(s)
1.
Gas valve closed
2.
Intake tube clogged
Air pressure too low
1.
System is leaking
2.
Oil level too low
For technical questions call 1-800-665-8685
Suggested Solution(s)
1.
Open
2.
Inspect and unclog
Increase appropriately (see
Specifications)
1.
Check all components and
accessories for leaks,
repairing or replacing as
needed
2.
Check and refill as needed
V1.0