English
Before charging
While charging
Charging
Pilot lamp
complete
(red)
Overheat
standby
Charging
impossible
○ Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are as
shown in Table 3, and batteries that have become hot
should be cooled for a while before being recharged.
Rechargeable
batteries
BSL1815S, BSL1815,
BSL1825
4
Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by
pulling on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out the
battery from the battery charger.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might
be low when using them the fi rst and second time.
This is a temporary phenomenon, and normal time
required for recharging will be restored by recharging
the batteries 2–3 times.
12
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Blinks
Lights continuously
Lights
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Blinks
Lights for 1 second. Does not light for
0.5 seconds. (off for 0.5 seconds)
Blinks
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Flickers
Table 3
Temperatures at which the
battery can be recharged
32°F–122°F (0°C–50°C)
Table 2
CAUTION
● When the battery charger has been continuosly
used, the battery charger will be heated, thus
constituting the cause of the failures. Once the
charging has been completed, give 15 minutes
rest until the next charging.
● If the battery is charged while it is heated
because it has been left for a long time in a
location subject to direct sunlight or because the
battery has just been used, the pilot lamp of the
charger lights for 1 second, does not light for 0.5
seconds (off for 0.5 seconds).
The battery will not be recharged. In such a case,
let the battery cool before charging.
● When the pilot lamp fl ickers (at 0.2-second
intervals), check for and take out any foreign
objects in the charger's battery connector. If
there are no foreign objects, it is probable that
the battery or charger is malfunctioning. Take it
to your authorized Service Center.
NOTE
○ Charging times may be longer depending on the
surrounding temperature and battery conditions.
○ Charge time lamp indications are only a guide, and
may vary depending on the surrounding temperature
and battery conditions.
○ Remove the battery from the charger when not in use.
How to make the batteries perform longer.
○ Recharge the batteries before they become
completely exhausted.
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)
Malfunction in the battery or
the charger