  • Page 1 BEDIENUNGSANLEITUNG USER MANUAL MODE D'EMPLOI MANUAL DEL USUARIO LED D-12 RGBA Flower Effect © Für weiteren Gebrauch aufbewahren! Copyright Keep this manual for future needs! Nachdruck verboten! Gardez ce mode d’emploi pour des Reproduction prohibited! utilisations ultérieures! Réproduction interdit! Guarde este manual para posteriores usos. Prohibida toda reproducción.
  • Page 2 MULTI-LANGUAGE-INSTRUCTIONS Inhaltsverzeichnis / Table of contents Sommaire / Contenido EINFÜHRUNG ..................................4 SICHERHEITSHINWEISE ..............................4 BESTIMMUNGSGEMÄßE VERWENDUNG........................6 INSTALLATION.................................. 7 Überkopfmontage................................7 Anschluss ans Netz................................. 8 BEDIENUNG..................................9 REINIGUNG UND WARTUNG ............................9 Sicherungswechsel ................................. 9 TECHNISCHE DATEN..............................10 INTRODUCTION................................11 SAFETY INSTRUCTIONS ..............................
  • Page 3 You can find the latest update of this user manual in the Internet under: Vous pouvez trouvez la dernière version de ce mode d'emploi dans l'Internet sous: Vd. puede encontrar la versión más reciente de este manual en el Internet bajo: www.eurolite.de 3/31 00039640.DOC, Version 1.1...
  • Page 4 - sich die letzte Version der Anleitung im Internet herunter laden EINFÜHRUNG Wir freuen uns, dass Sie sich für einen EUROLITE LED D-12 RGBA Flowereffekt entschieden haben. Wenn Sie nachfolgende Hinweise beachten, sind wir sicher, dass Sie lange Zeit Freude an Ihrem Kauf haben werden.
  • Page 5 Das Gerät darf nicht in Betrieb genommen werden, nachdem es von einem kalten in einen warmen Raum gebracht wurde. Das dabei entstehende Kondenswasser kann unter Umständen Ihr Gerät zerstören. Lassen Sie das Gerät solange uneingeschaltet, bis es Zimmertemperatur erreicht hat! Bitte überprüfen Sie vor der ersten Inbetriebnahme, ob kein offensichtlicher Transportschaden vorliegt.
  • Page 6 Kinder und Laien vom Gerät fern halten! Das Gerät darf niemals unbeaufsichtigt betrieben werden! BESTIMMUNGSGEMÄßE VERWENDUNG Bei diesem Gerät handelt es sich um einen Effektstrahler, mit dem sich dekorative Lichteffekte erzeugen lassen. Dieses Produkt ist nur für den Anschluss an 230 V, 50 Hz Wechselspannung zugelassen und wurde ausschließlich zur Verwendung in Innenräumen konzipiert.
  • Page 7 Soll das Gerät transportiert werden, verwenden Sie bitte die Originalverpackung, um Transportschäden zu vermeiden. Achten Sie bitte unbedingt darauf, dass das Gerät im Lieferzustand verpackt wird. Beachten Sie bitte, dass eigenmächtige Veränderungen an dem Gerät aus Sicherheitsgründen verboten sind. Wird das Gerät anders verwendet als in dieser Bedienungsanleitung beschrieben, kann dies zu Schäden am Produkt führen und der Garantieanspruch erlischt.
  • Page 8 Vergewissern Sie sich vor der Montage, dass die Montagefläche mindestens die 10-fache Punktbelastung des Eigengewichtes des Gerätes aushalten kann. BRANDGEFAHR! Achten Sie bei der Installation des Gerätes bitte darauf, dass sich im Abstand von mind. 0,5 m keine leicht entflammbaren Materialien (Deko, etc.) befinden. Befestigen Sie das Gerät über einen geeigneten Haken an Ihrem Traversensystem.
  • Page 9 Lichteffekte dürfen nicht über Dimmerpacks geschaltet werden. BEDIENUNG Wenn Sie das Gerät an die Spannungsversorgung angeschlossen haben, nimmt der LED D-12 RGBA den Betrieb auf. Dank des eingebauten Mikrofones ist kein Controller nötig, und die Strahlen werden musikgesteuert durch den Raum geworfen. Die Empfindlichkeit kann mit Hilfe des Drehreglers an der Geräterückseite beeinflusst werden.
  • Page 10 Wenn die Anschlussleitung dieses Gerätes beschädigt wird, muss sie durch eine besondere Anschluss- leitung ersetzt werden, die von Ihrem Fachhändler erhältlich ist. Sollten Sie noch weitere Fragen haben, steht Ihnen Ihr Fachhändler jederzeit gerne zur Verfügung. TECHNISCHE DATEN Spannungsversorgung: 230 V AC, 50 Hz ~ Gesamtanschlusswert: 35 W Musiksteuerung:...
  • Page 11 - download the latest version of the user manual from the Internet INTRODUCTION Thank you for having chosen a EUROLITE LED D-12 RGBA Flower Effect. If you follow the instructions given in this manual, we are sure that you will enjoy this device for a long period of time.
  • Page 12 Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C connection cable or on the casing, do not take the device into operation and immediately consult your local dealer. This device falls under protection-class I. The power plug must only be plugged into a protection class I outlet.
  • Page 13 This device is designed for professional use, e.g. on stages, in discotheques, theatres etc. Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects. Do not shake the device. Avoid brute force when installing or operating the device. When choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture or dust.
  • Page 14 INSTALLATION Overhead rigging The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation. The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
  • Page 15 carbines must be sufficiently dimensioned and used correctly in accordance with the latest industrial safety regulations (e. g. BGV C1, BGI 810-3). Please note: for overhead rigging in public or industrial areas, a series of safety instructions have to be followed that this manual can only give in part.
  • Page 16 CLEANING AND MAINTENANCE The operator has to make sure that safety-relating and machine-technical installations are inspected by an expert after every four years in the course of an acceptance test. The operator has to make sure that safety-relating and machine-technical installations are inspected by a skilled person once a year.
  • Page 17 TECHNICAL SPECIFICATIONS Power supply: 230 V AC, 50 Hz ~ Power consumption: 35 W Sound-control: via built-in microphone Maximum ambient temperature T 45° C 60° C Max. housing temperature T (steady state): Minimum distance from flammable surfaces: 0.5 m Minimum distance to lighted object: 0.1 m Fuse: F 1 A, 250 V...
  • Page 18 - télécharger la version ultérieure du mode d'emploi d'Internet INTRODUCTION Nous vous remercions d'avoir choisi un EUROLITE DEL D-12 RGBA Effet Flower. Si vous respectez les instructions de service suivantes, vous allez profiter longtemps de votre achat. Le DEL D-12 RGBA dispose d'un microphone integré.
  • Page 19 Avant tout, assurez-vous que l'appareil n'a pas subi de dommage lors de son transport. Si l'appareil ou le câble d'alimentation est endommagé, ne jamais mettre l'appareil en service. Contactez immédiatement votre revendeur. La construction de l'appareil correspond à la classe de protection I. La fiche secteur doit être connectée uniquement à...
  • Page 20 Tenir les enfants et les novices éloignés de l'appareil. Ne jamais faire marcher sans surveillance. EMPLOI SELON LES PRESCRIPTIONS Cet appareil est un effet lumineux pour créer des effets décoratifs. Cet appareil doit seulement être connecté avec une tension alternative de 230 V, 50 Hz et a été conçu pour un usage dans des locaux clos. Cet appareil est prévu pour des utilisations professionnelles, p.
  • Page 21 Si vous deviez transporter l'appareil, utilisez l'emballage d'origine pour éviter tout dommage. Assurez-vous que vous enviez l’appareil dans l’etat original. Ne nettoyez pas l'appareil avec des produits de nettoyage trop puissants ou abrasifs. Utilisez un chiffon doux, humide. Notez que pour des raisons de sécurité, il est interdit d'entreprendre toute modification sur l'appareil. Si l'appareil est utilisé...
  • Page 22 Rassurez-vous avant le montage que la surface de montage peut supporter au moins dix fois la charge ponctuelle du poids propre de l'appareil. DANGER D'INCENDIE! Assurez-vous lors du montage qu'il n'y ait pas de matériau facilement inflammable en contact avec le boîtier (distance minimale 0,5 m)! Fixez l'appareil via un crochet approprié...
  • Page 23 Ne jamais connecter des effets lumineux à un "dimmer pack". MANIEMENT Le DEL D-12 RGBA commençera à fonctionner dès que vous le brancherez au secteur. Le mouvement de rayons est contrôlé par le microphone integré, donc on n'a pas besoin de contrôleur. La sensibilité...
  • Page 24 CARACTÉRISTIQUES TECHNIQUES Alimentation: 230 V AC, 50 Hz ~ Puissance de rendement: 35 W Contrôle par le son: grâce au microphone intégré 45° C Maximale température ambiante T Maximale température du boîtier (à l'équilibre) T 60° C Distance minimum aux surfaces enflammables: 0,5 m Distance minimum à...
  • Page 25 -descargar la última versión del manual del Internet INTRODUCCIÓN Gracias por haber elegido un EUROLITE LED D-12 RGBA Efecto Flower. Si Vd. respecte las instrucciones sucesivas, aseguremos que vaya a gozarse mucho de su compra. El LED D-12 RGBA dispone de un micrófono integrado.
  • Page 26 Si el aparato ha estado expuesto a grandes cambios de temperatura (p.e. tras el transporte), no lo enchufe inmediatamente. La condensación de agua producida podría dañar su aparato. Deje el aparato desconec- tado hasta que llegue a la temperatura ambiente. Antes de la puesta en marcha inicial, por favor asegúrese de que no hay daños causados durante el transporte.
  • Page 27 No agite el aparato. Evite hacer excésiva fuerza durante la instalación y el manejo del aparato. Cuando buscar el sitio de instalación, por favor asegúrese de que el aparato no está expuesto a calor extremo, humedad o polvo. No debe haber cables mal instalados o no fijados correctamente. ¡Se pone usted en peligro y pone en peligro a otros! Nunca operar o almacenar el aparato en un ambiente con agua proyectada, lluvia, humedad o humo.
  • Page 28 La suspensión del aparato debe ser fabricado de una manera que puede llevar 10 vezes la carga por una hora sin sufrir deformaciones dañosas permanentes. La instalación siempre debe ser efectuada con una segunda suspensión independiente, por ejemplo una red de anclaje apropriada.
  • Page 29 Por favor tenga en cuenta que una montaje por encima de la cabeza en los lúgares públicos y comerciales requira el mantenimiento de muchos preceptos que podemos mencionar sólo parcialmente en este manual. El operador debe procurar el mismo las instrucciones de seguridad válidas y debe seguirlas! El fabricante no acepta responsabilidad por ningunos daños originados por la instalación inadecuada y medidas de seguridad insuficientes! Insere el cable de anclaje en el ojete de seguridad y en el trussing u un lugar de fijación seguro.
  • Page 30 Durante la inspección, los puntos siguientes deben ser observados: 1) Todos tornillos con cuales el aparato o partes del aparato están montado, deben ser atornillados fijamente y no deben ser corroídos. 2) No debe haber deformaciones en la caja, fijaciones y el sitio de instalación (techo, abajamiento, trussing).