2. INSTALLATION INSTRUCTIONS
ALL APPLIANCES MUST BE FITTED AND OR CONVERTED BY AREGISTERED INSTALLER, IN ACCORDANCE WITH
CURRENT REGULATIONS.
INSTALLATION
1. Appliances are designed to be installed, on factory for stability, should they be fitted on any other surface
they should be suitably secured, to prevent excessive movement. All appliances must not be installed on or
against any combustible surface.
2. Appliances are supplied in for use with either Natural Gas or LPG. The required gas type must be specified
at the point of order. Natural Gas appliances have an LPG conversion kit included as standard. Conversion
kits for LPG models must be purchased separately.
3. Clearances around appliances must be:
CEILING/SHELF
REAR
SIDES
It should be noted that the sides of the appliance will get hot and appliances with components sensitive to
heat, should not be placed directly next to the unit.
4. Leg Installation see picture at down, The leg channel is located on the package base. This channel must be
installed when using the legs.
5. Connection to the appliance is by ½ BSPT at the rear of the appliance.
6. Pressure test point is located at rear of appliance.
7. The low rate adjuster is factory set and sealed for natural gas. If a unit needs to be converted, the qualified
engineer must reseal the low rate adjuster after conversion.
8. Remove all protective film before use.
9. Ensure whoever is operating the appliance is fully conversant with its operation and aware of dangers
involved in incorrect operation and cleaning, especially the danger of burns or scalds from the cooking
medium and hot surfaces of working areas.
10. These appliances are to be installed with sufficient ventilation to prevent the occurrence of unacceptable
concentrates of substances harmful to health in the room in which they are installed.
11. During installation provision must be made for combustion air supply to the appliance, which enters the
appliance through the base and rear of the appliance, this should not be blocked at any time. SEE TECHNICAL.
1500mm
350mm
100mm
www.combisteel.com