Operating manual
CONNECTING THE HOOVER
1 - Connect the unlubricated compressed air supply, not exceeding 10 bar, to
connector 1.
2 - Turn knob 2 to activate the suction.
3 - The operating pressure of the sander can be adjusted with the knob 3.
4 - Pressure gauge 4 indicates the operating pressure of the sander.
5 - Insert the duct into hole 1.
6 - Connect suction hose 2 and sander supply 3 (G1/4)
7 - Connect hose 4 to the hoover.
FAILURES AND ANOMALIES
Failures
The hoover does not
work
The sander does not
work
The hoover blows air
instead of sucking.
Translation of the original
instructions
Check that the hoover is connected to the unlubricated
compressed air network.
Press the start button.
Check the pressure gauge inside the hoover.
It is set at the factory and should be at 3.5 bar.
Check that no hoses are pinched or disconnected.
Check that the bag or the duct is not blocked.
Check that the pneumatic hose is connected.
Check that the pressure gauge 1 indicates a pressure
of around 4 bar, otherwise adjust using the knob.
the bag is full or clogged.
The suction system is clogged (grease suction, or
air connection to lubricated network). A procedure is
available for dismantling and cleaning the suction unit.
3
Anomalies
GYSDUST EXTRACTOR
2 1
4
2&3
4
1
2
1
17