Télécharger Imprimer la page

Ravelli RBC 8010 Manuel D'utilisation Et D'entretien page 70

Masquer les pouces Voir aussi pour RBC 8010:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Rev.0 17.07.19
Pag.70
EN
GENERIC ALARM
ANOMALY (general)
Warning Pop-Up
Adjust RDS
RDS SYSTEM ADJUSTMENT
system
(only if the RDS system is provi-
SERVICE REQUEST
AIR FLOW METER FAILU-
(only if the RDS system is provi-
modulate
SIGNALLING
• The door and the ash box are not closed correctly
• Poor combustion in grate.
RUN
BRAZIER CLEANING
(only if the RDS system is
• Presence of foreign body in air intake tube.
provided)
• The air flow meter may be dirty.
The appearance of the message "ADJUST THE RDS SYSTEM" indicates that the initial parameter testing procedure and
calibration has been unsuccessfully. This indication does not block the stove.
TITLE
TRIAL
AL 01
BLACK OUT
AL 02
FUME PROBE
AL 03
FUME OVERTEMP.
AL 04
FUME EXHAUST DAMAGED
AL 05
NO SWITCH-ON
Use and maintenance manual RBC 8010 - RBC 8012
The stove is in alarm state; refer to the throubleshooting chapter.
The stove has detected an anomaly; refer to the throubleshooting chapter.
FLAME
It shows that the testing procedure and initial parameter calibration have not been completed
REQUEST
or have been performed incorrectly. This indication, however, does not block the stove.
ded)
The threshold value of set work hours has been reached. The symbol displayed remains
active throughout the work phase. Non-routine maintenance is required on the stove.
It shows a failure of the air flow meter and the stove switches to minimum capacity disabling
RE
the RDS system.
ded)
REASON
- No voltage during work phase
- The fume probe is malfunctioning
- The fume probe is disconnected from the
electronic board
- Combustion in the brazier is not optimal due to
clogging or obstructions of internal stove ducts
- The tangential fan (if provided) is
malfunctioning or damaged
- Fume exhaust encoder is not working or is
connected incorrectly
- No power to fume exhaust system
- The fume exhaust system is blocked
- The pellet tank is empty
- Pellet calibration and suction during switch on
phase is incorrect.
- The igntition coil is faulty or positioned
DESCRIPTION
• Make sure they are properly closed.
• Switch off the stove, clean the brazier and check the cleanliness of the
support bench, clean the tube bundle by activating the turbolators. and
adjust the combustion through Pellet/Air settings.
• Check for any foreign body and remove it
• Clean the flow meter with the stove in "Switched off" state
• Contact the Support Service
REASON
SOLUTION
SOLUTION
- Press the switch off key and switch on
boiler switch-on.
- If the problem persists, contact the Support
Service
- Contact the Support Service
- Contact the Support Service
- Switch off the stove, clean the brazier and the
tube bundle and adjust the combustion setting
the Pellet/Air values
- Contact the Support Service
- If the problem persists, contact the Support
Service
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Check for the presence of pellets in the
container. Top up, if necessary.
- Contact the Support Service
- Contact the Support Service

Publicité

loading

Ce manuel est également adapté pour:

Rbc 8012