For safes equipped with an electronic lock:
What should you do before using the safe for
the first time?
Please check that the safe works correctly
before installing it or securing items inside.
Attention
• The battery could already be fitted by the
factory and the lock can be operated directly
go to "Code". If not please follow the procedure
on "Replacing the battery" or "Emergency
power supply".
Green LED
Red LED
Bar handle
Code
The electronic lock is supplied by the manufacturer
with the standard access code 1 2 3 4 5 6. This
code must be changed before you use the safe.
Now do the following:
1. Press ON.
2. Open lock with the standard access
code 1 2 3 4 5 6.
3. Within 4 seconds turn bar handle clockwise
until stop position reached.
4. Open the door. Now change the access code;
this is done as follows:
Changing the access code
Note: this can only been done when the safe is
unlocked and the door is open.
1. Press ON.
2. Press P.
3. Enter the standard access code
1 2 3 4 5 6.
4. Enter now your personal 6-digit code.
5. Enter now your personal 6-digit code
again.
6. DO NOT CLOSE THE DOOR YET!; test the
new code before closing the safe.
7. If testing has been carried out successfully,
you can close the door and lock the safe.
Note:
If the new personal access code as per 5) was
incorrectly confirmed, the signal 3 x
appears.
Repeat the sequence from 1).
04
Closing the safe
Close the door and keep it gently pressed shut with
one hand. Now turn the bar handle anti-clockwise
until it stops.
Opening the safe
1. Press ON.
2. Open lock with your 6-digit personal
access code.
3. Within 4 seconds turn bar handle clockwise
until stop position reached.
4. The door can be opened further by pulling the
bar handle towards you.
Opening after 3 or more incorrect code entries
> penalty time
After 3 incorrect code entries the lock goes into a
one minute blocked status. The period in which the
lock is blocked is extended to 2, 4, 8 and a
maximum of 16 minutes every time an incorrect
code is entered. During this period the red LED
flashes every second and it is not possible to enter
any further codes.
1 x
Replacing the battery
1 x
When the batteries are weak 10 x
will appear
after pressing ON.
Replace the batteries as soon as possible. We
recommend that you use only alkaline model
MN1604 - 9V batteries.
To replace the battery, follow these steps:
1. Open the door.
2. Open the lid of the battery compartment at the
back of the door (if necessary remove the door
cover).
1 x
3. Replace the battery; ensuring that the positive
1 x
and negative terminals are aligned correctly; do
this as follows:
1 x
4. Press the catch on the top edge of the battery
/
cover with a screwdriver and lever off the
2 x
battery lid. Pull the battery out carefully until
the battery clip is visible. Release the battery
1 x
from the clip and replace. Re-engage the lid.
Please ensure that the cable is not damaged.
5. DO NOT CLOSE THE DOOR YET!; test the
new code before closing the safe.
6. If the lock works correctly, you can close the
safe.
Notes:
• You have 20 seconds for each entry keyed in.
If you have not pressed a key within this 20
second period, the electronic system will close
1 x
down automatically. Operations not fully
completed have to be re-started.
1 x
• Code entries can be interrupted by pressing the
P button.
Emergency power supply
If the battery is discharged with the door locked,
the lock can be powered up using the emergency
power supply connection. To do this, a 9-volt block
battery must be connected to the supply clip
beneath the cover of the control unit.
1. Press tool into the right hand hole on the
bottom edge of the control unit until the catch
is released. Keep the tool pressed down whilst
the cover raising carefully.
2. Repeat this process on the left hand hole. Lift
off the cover carefully.
3. Pull out the battery clip for the emergency sup
ply by about 1 cm and clip in a 9 volt block
battery. Open the lock with a valid code,
remove the block battery from the clip and
replace the discharged battery in the lock case.
4. Replace the cover and press down until all four
catches are engaged. Check that the lock
functions correctly whilst the safe is still open.
Attention
• Do not store your user manual in the safe, but
safely away from the safe.
Cover
Raise here
Tool
05