Troubleshooting
This section describes possible system problems and their solutions:
Always perform the following preliminary checks before referring to the troubleshooting table:
Perform a complete visual inspection of the Ind. LuNAR RK200DTG3, for signs of mechanical
damage, loose connections or torn wires.
Check the connections of the incoming AC power source.
Trouble
ProSYS Configuration of
detectors fails/not accepted by
the system
Tamper indication while working
in the BUS mode
Tamper indication in the Relay
or BUS mode
Walk test cannot be initiated via
the ProSYS keypad
Green LED doesn't operate
during Walk test - MW channel
does not function
Meaning
ID configuration
Disconnect all power sources,
problem
configure the desired IDs and
reconnect power again
Tamper
Verify that both DIP 8 and 9 are in
connection
ON position
malfunction
Tamper probably
Visually verify that ceiling tamper
not closed
and spring are correctly installed
Wrong code
Insert the appropriate code
Ind. LuNAR
Normal behavior
RK200DTG3 is
configured (via
the ProSYS) to
the "MW disable
on DISARM"
during ProSYS's
DISARM mode
Ind. LuNAR
Reset the detector.
RK200DTG3
If MW channel trouble reoccurs,
operating in
replace the detector with a new one
Bypass mode
due to "Bypass
MW channel
mode"
Ind. LuNAR RK200DTG3 Installation Guide
Response