13.TROUBLESHOOTING
PROBLEM
1. The pump does
not deliver any liquid
2. The pump does
not reach the desired
pressure
3. The device stops
the pump from
running even in
presence of water
4. The pump does
not start when a tap
is opened
5. The pump starts
and stops frequently
6. The pump keeps
running and does not
stop
POSSIBLE CAUSE
1. The Hidrotank-H1 was
mounted the other way round
2. The priming process was
not implemented correctly
3. The suction hose is not
properly immersed in the liquid
1. There are leaks in the
system
2. The hose or suction filters
are clogged
3. The foot valve is blocked
1. The pressure is set too high
2. The pump's thermal
protection may prevent the
pump from running
1. The pressure is set too low
1. There are leaks in the
system
2. The pressure within the
pressure tank is not correct
3. The flow of water from the
tap is too low
1. The flow switch of the
Hidrotank-H1 is dirty
2. There are significant leaks
within the system
3. A check valve has been
installed before or after the
Hidrotank-H1 device
SOLUTION
1. Check the installation of
the device and correct if
necessary
2. Press and hold the RESET
button until the flow is regular
3. Check that the suction
hose is well immersed in
water
1. Check for leaks
2. Remove any clogging
3. Replace the foot valve
1. Decrease the pressure
until the problem is resolved.
Contact a professional
installer.
2. Check the pump
1. Increase the pressure until
the problem is resolved.
Contact a professional
installer
1. Check for any leaks and
resolve as necessary
2. Restore the pre-set value
of the pressure tank
3. Contact technical support
1. Check the device
2. Check the plumbing
system
3. Remove any valves from
the system
18